  • B contact of AL/AX

    "b contact" is normally closed contact, and It is also called "NC (Normally Closed) contact". More Details >>

    • No:22435
    • Release Date:2018/08/31 14:33
  • Micro-load AL and AX switch

    It is possible to produce micro-load AL and AX switch for MCCBs/ELCBs. However, if you need the products compatible with the standards (CE marking product an... More Details >>

    • No:22413
    • Release Date:2018/08/31 14:33
  • AL/AX/SHT/UVT terminal markings and wire colors

    The color of terminal identification tube and lead wire is same.For one AL switch, 98/ALa terminal : red, 96/ALb terminal : blue, 95/ALc terminal : grayFor S... More Details >>

    • No:22396
    • Release Date:2018/08/31 14:33
  • AL

    AL (Alarm switch) is a switch which electrically displays tripping state of a circuit breaker.The markings of the switch are 8/ALa, 96/ALb and 95/ALc.*When t... More Details >>

    • No:22350
    • Release Date:2018/08/31 14:33
  • Lifetime with SHT or UVT

    The number of trip durability by using SHT and UVT is 10% of the opening/closing number including the number of trips by overcurrent, trip button and test bu... More Details >>

    • No:22407
    • Release Date:2018/08/31 14:33
  • Type name of the operating handle

    F-2SV is standard, F-2SVE is for emergency use. The difference is the color of the handle and its surroundings parts. More Details >>

    • No:38028
    • Release Date:2021/01/22 17:37
  • A contact of AL/AX

    "a contact" is normally opened contact, and It is also called "NO (Normally Opened) contact". More Details >>

    • No:22410
    • Release Date:2018/08/31 14:33
  • Insulating barrier in the package

    Use the insulation barrier if they are packed with. If not using that, breaking performance is not guaranteed. For models that the insulation barrier is not ... More Details >>

    • No:22406
    • Release Date:2018/08/31 14:33
  • Operation handle CE marking

    The operating handle is an external accessory for a circuit breaker and there is no safety standard for the operating handle itself. Therefore, there is no C... More Details >>

    • No:22408
    • Release Date:2018/08/31 14:33
  • Where UVT power supplied from?

    Do not take the control power supply of UVT ("Resettable type" and "Reset prevention type") from the secondary side of the breakers. If taking the control po... More Details >>