If both of a closing coil and a tripping coil are continued to excite at thesame time, it will result in coil burnout. You need to design a system thatdoes n... More Details >>
- No:23282
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
Inrush current does not flow since the full voltage directly applys theelectromagnet of SD-Q* and only resistance component of theelectromagnet limits the cu... More Details >>
- No:23277
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
It means the rated operating voltage (nominal voltage) range andfrequency (when AC operation) of a control coil. More Details >>
- No:23266
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
In the withstand voltage test, AC 1500V is applied for 1 min However, apressurizing part is only between a terminal part (conductive part) and amounting surf... More Details >>
- No:23377
- Release Date:2018/09/12 15:12
-
About Low-voltage Power Distribution Products
Collective control or individual control can be selected for control circuit ofUS-H* type and it is possible to apply to single-phase circuit or three-phase ... More Details >>
- No:23366
- Release Date:2018/09/12 15:12
-
About Low-voltage Power Distribution Products
We do not provide it. More Details >>
- No:23350
- Release Date:2018/09/12 15:12
-
About Low-voltage Power Distribution Products
We can provide "CAN terminal" products for only US-N20?50(TE) type asspecial product.Type name:US-N20?50(TE)CX More Details >>
- No:23337
- Release Date:2018/09/12 15:12
-
About Low-voltage Power Distribution Products
It is possible to replace it by user. More Details >>
- No:23321
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
The minimum applicable load is as follows. Contact reliability is indicatedby fault rate λ60 (Number of fault / Operating cycles per one contact) atthe relia... More Details >>
- No:23320
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
The minimum applicable load voltage and current are as follows. Contactreliability is indicated by fault rate λ60 (Number of faults / Operatingcycles per one... More Details >>
- No:23290
- Release Date:2018/09/12 15:11