FAQ


FAQAbout Products
- FAQ > Low-voltage Power Distribution Products > Contactors and Motor Starters > Motor Starters
FAQ
Keyword Search
FAQ within [ Motor Starters ]
-
About Low-voltage Power Distribution Products
There is no polarity in the control coil. More Details >>
- No:23311
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
It is possible to install them by rotating 90℃ to the right or left from theregular installation except S-N600 and S-N800. It is not possible to rotate180℃ f... More Details >>
- No:23335
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
The interlock allows only one magnetic starter to be turned"ON" and notanother opposit side magnetic starter in the case that two magneticstarters must not b... More Details >>
- No:23244
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
For US-N/K/H type, since current is opened/closed by semiconductorelement, there is no lifetime related to operating cycles, but werecommend to replace in 10... More Details >>
- No:23274
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
Time rating is 60sec and the rest time is for 2 hours. More Details >>
- No:23308
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
US-N* type can be used for AC power supply motor, heater, lighting loadand capacitor load etc. More Details >>
- No:23365
- Release Date:2018/09/12 15:12
-
About Low-voltage Power Distribution Products
Since it is necessary to energize the pole containing a heater element of athermal load relay, you need to connect it to both side of 3 poles(Between 1/L1-2/... More Details >>
- No:23249
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
You can install it as follows.1. Regular installation of the power supply side terminal as the upper partand the load side terminal as the lower side2. Incli... More Details >>
- No:23283
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
It is not possible to produce an enclosed magnetic starter with a saturatedreactor. More Details >>
- No:23370
- Release Date:2018/09/12 15:12
-
About Low-voltage Power Distribution Products
The contacts are closed by electrical (closing coil) or mechanical operationand even if the operating force is removed, the closed state is maintainedby the ... More Details >>
- No:23253
- Release Date:2018/09/12 15:11
111-120 of Total 142