FAQ
FAQAbout Products
- FAQ > Low-voltage Power Distribution Products > Contactors and Motor Starters > Motor Starters
FAQ
Keyword Search
FAQ within [ Motor Starters ]
-
About Low-voltage Power Distribution Products
It has 1,000 times electrical durability using rated currents. More Details >>
- No:23315
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
The main circuit of US-N* type applies only AC power supply product. ForDC circuit, US-KD8 type solid state contactor can be used. More Details >>
- No:23314
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
There is no polarity in the control coil. More Details >>
- No:23311
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
This is because the delay time becomes shorter since the rebound force ofa spring against the suction force of a magnetic contactor increases if thecontact "... More Details >>
- No:23309
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
In the withstand voltage test, 2500V is applied for 1 min. The appliedlocation is as follows.1. Between the conductive part and the grounded metal part, and ... More Details >>
- No:23305
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
The minimum applicable load is 20V, 3mA . Contact reliability is indicatedby fault rate λ60 (Number of fault / Operating cycles per one contact) atthe reliab... More Details >>
- No:23304
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
There are auxiliary contact (UQ-AX2、UQ-AX2KR) units that can apply forQ11 frame and QR11 frame.1. UQ-AX2 can apply for the left side of Q11 and QR11.2. UQ-AX... More Details >>
- No:23302
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
The fault detection contact of the cooling fan detects the temperature ofthe fin in the solid state contactor and operates when exceeding thespecified value.... More Details >>
- No:23301
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
Since a triac element in UT-SY21 type and UN-SY11/21/31 canopen/close, surge voltage does not occur. Therefore, a coil surgesuppressor is not needed for them. More Details >>
- No:23300
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
It is possible to apply for single-phase circuit. However, it may be lesseffect in single-phase circuit (100 V, etc) since low voltage circuit is tendedto be... More Details >>
- No:23297
- Release Date:2018/09/12 15:11
111-120 of Total 142