FAQ


FAQAbout Products

- FAQ > Low-voltage Power Distribution Products > Contactors and Motor Starters > Motor Starters
FAQ
Keyword Search
FAQ within [ Motor Starters ]
-
About Low-voltage Power Distribution Products
It is possible to install them by rotating 90℃ to the right or left from theregular installation except S-N600 and S-N800. It is not possible to rotate180℃ f... More Details >>
- No:23335
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
We have a transparent protective cover of live part for US-H20(DD) to US-H50(DD) that can be installed easily as an optional part. The type nameis UN-CV501US. More Details >>
- No:23347
- Release Date:2018/09/12 15:12
-
About Low-voltage Power Distribution Products
The consumption VA of a control circuit is 7VA for AC 100V product and14VA for AC 200 V product. More Details >>
- No:23348
- Release Date:2018/09/12 15:12
-
About Low-voltage Power Distribution Products
It is not possible to add it. More Details >>
- No:23362
- Release Date:2018/09/12 15:12
-
About Low-voltage Power Distribution Products
It is possible to produce, however, it may cause unnecessary trippingwhen using inching. More Details >>
- No:23373
- Release Date:2018/09/12 15:12
-
About Low-voltage Power Distribution Products
The functions of 2 and 3 element type are almost same, but since theneutral pole (3/L2, 4/T2) of 3-pole 2-element type is connected inside, itis not possible... More Details >>
- No:23270
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
Surge voltage occurs due to opening/closing a control coil. Since we donot provide the surge suppressor for a control coil which is available forthem, you ne... More Details >>
- No:23285
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
It is a current value that can be closed (turning contact "ON") under theconditions specified in the standards. (In IEC, number of tests is 50times) More Details >>
- No:23294
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
It is possible to produce with the coil designation of less than AC 230V andDC 220V. Please add " SA" at the end of the type name. More Details >>
- No:23319
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
It is possible to operate it by using two US-N* type. For the interlock ofboth US-N* type, UA-RE type reversible unit is used. More Details >>
- No:23375
- Release Date:2018/09/12 15:12
111-120 of Total 142