When carrying the rated current at ambient temperature of 40℃, themaximum temparature of cooling fin is approximately 90℃. More Details >>
- No:23360
- Release Date:2018/09/12 15:12
-
About Low-voltage Power Distribution Products
Standard product of US-N* type has a terminal cover. Moreover, UA-DR1/UA-SH1 driving-unit has a terminal cover as option. More Details >>
- No:23352
- Release Date:2018/09/12 15:12
-
About Low-voltage Power Distribution Products
We have a transparent protective cover of live part for US-H20(DD) to US-H50(DD) that can be installed easily as an optional part. The type nameis UN-CV501US. More Details >>
- No:23347
- Release Date:2018/09/12 15:12
-
About Low-voltage Power Distribution Products
It is time from magnetizing or demagnetizing a control coil to operatingcontact (turning contact "ON" or "OFF"). More Details >>
- No:23343
- Release Date:2018/09/12 15:12
-
About Low-voltage Power Distribution Products
It is possible to produce with the coil designation of less than AC 230V andDC 220V. Please add " SA" at the end of the type name. More Details >>
- No:23319
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
Since the leakage currents exist in a solid state contactor such as US-N/K/H type even when it is "OFF" state, it can not be used for insulatingload equipmen... More Details >>
- No:23288
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
It is a circuit flowing small current (A few dozen Ma to several A) such ascontrol coil and indicator light circuit of magnetic contactor and itopens/closes ... More Details >>
- No:23257
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
The contacts are closed by electrical (closing coil) or mechanical operationand even if the operating force is removed, the closed state is maintainedby the ... More Details >>
- No:23253
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
The interlock allows only one magnetic starter to be turned"ON" and notanother opposit side magnetic starter in the case that two magneticstarters must not b... More Details >>
- No:23244
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
It is also called jogging and it means frequently opening and closing thestarting currents such as small movement of a motor. More Details >>
- No:23242
- Release Date:2018/09/12 15:11