FAQ


FAQAbout Products
- FAQ > Low-voltage Power Distribution Products > Contactors and Motor Starters > Motor Starters
FAQ
Keyword Search
FAQ within [ Motor Starters ]
-
About Low-voltage Power Distribution Products
You must not desassemble it since mechanical latched type has beenadjusted and tested at our factory. More Details >>
- No:23325
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
It can not be connected in parallel since the characteristics of each US-N/K/H type elements are differenct and the currents are unbalanced whenconnecting in... More Details >>
- No:23317
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
It is a film capacitor, not electrolytic capacitor. More Details >>
- No:23316
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
The main circuit of US-N* type applies only AC power supply product. ForDC circuit, US-KD8 type solid state contactor can be used. More Details >>
- No:23314
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
You need to connect the two terminal of No.15, 16 or 18 terminal to theload side of the contactor. (The remaining terminal is unnecessary toconnect.) More Details >>
- No:23307
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
DIN rail can be added to 5A frame and 8A frame of US-N* type asstandard and 20A frame as special product. Type name : US-N5SS(TE),US-N5SS(TE), US-N20(TE)RMMo... More Details >>
- No:23306
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
It is a coil that opens/closes a magnetic contactor by magnetizing(applying suction force) or demagnetizing an electromagnet core. More Details >>
- No:23303
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
The fault detection contact of the cooling fan detects the temperature ofthe fin in the solid state contactor and operates when exceeding thespecified value.... More Details >>
- No:23301
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
It is not possible to detect the voltage variation less than 100msec. More Details >>
- No:23293
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
Since US-N/K/H type is a solid state contactor having zero-voltage-triggering method, surge voltage does not occur due to opening/closing amain circuit. More... More Details >>
- No:23291
- Release Date:2018/09/12 15:11
111-120 of Total 142