FAQ
FAQAbout Products
- FAQ > Low-voltage Power Distribution Products > Contactors and Motor Starters > Motor Starters
FAQ
Keyword Search
FAQ within [ Motor Starters ]
-
About Low-voltage Power Distribution Products
Since the control coil of DU-N type is AC operation DC excitation methodof an electromagnet type and it includes the surge suppresing function.Therefore, a s... More Details >>
- No:23353
- Release Date:2018/09/12 15:12
-
About Low-voltage Power Distribution Products
Bearing lifetime of cooling fan is 10,000 to 35,000 hours. However, thelifetime of the cooling fan will be reduced depending on the ambienttemperature rise, ... More Details >>
- No:23364
- Release Date:2018/09/12 15:12
-
About Low-voltage Power Distribution Products
It is a product that can control two main circuit elements independently,and can be downsized when two or more single-pole type SSCs are used.It is also effe... More Details >>
- No:23376
- Release Date:2018/09/12 15:12
-
About Low-voltage Power Distribution Products
A thermal load relay is intended for burnout protection of three-phasesquirrel cage motor. When direct current is applied to the thermal loadrelay, the opera... More Details >>
- No:23281
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
We have a transparent protective cover of live part for US-H20(DD) to US-H50(DD) that can be installed easily as an optional part. The type nameis UN-CV501US. More Details >>
- No:23347
- Release Date:2018/09/12 15:12
-
About Low-voltage Power Distribution Products
Standard product of US-N* type has a terminal cover. Moreover, UA-DR1/UA-SH1 driving-unit has a terminal cover as option. More Details >>
- No:23352
- Release Date:2018/09/12 15:12
-
About Low-voltage Power Distribution Products
It is not possible to replace by customer since the magnetic contactorsused for S-T*DL type and S-N*DL type are different from the standardtype in the specif... More Details >>
- No:23354
- Release Date:2018/09/12 15:12
-
About Low-voltage Power Distribution Products
In our 3-contactor type star-delta starter (EYD), in order to eliminate thebreaking duty of the star contactor (MCS), the main contactor (MCM)break the star-... More Details >>
- No:23239
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
It can not be connected in parallel since the characteristics of each US-N/K/H type elements are differenct and the currents are unbalanced whenconnecting in... More Details >>
- No:23317
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
The minimum applicable load is as follows. Contact reliability is indicatedby fault rate λ60 (Number of fault / Operating cycles per one contact) atthe relia... More Details >>
- No:23320
- Release Date:2018/09/12 15:11