FAQ


FAQAbout Products
- FAQ > Low-voltage Power Distribution Products > Contactors and Motor Starters > Motor Starters
FAQ
Keyword Search
FAQ within [ Motor Starters ]
-
About Low-voltage Power Distribution Products
It is possible to apply for single-phase circuit. However, it may be lesseffect in single-phase circuit (100 V, etc) since low voltage circuit is tendedto be... More Details >>
- No:23297
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
Surge voltage occurs due to opening/closing a control coil. Since we donot provide the surge suppressor for a control coil which is available forthem, you ne... More Details >>
- No:23285
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
It means the rated operating voltage (nominal voltage) range andfrequency (when AC operation) of a control coil. More Details >>
- No:23266
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
A thermal load relay is set as full-load current of a motor. However, ifambient temperature is significantly different from 20℃ or the connectingwire is diff... More Details >>
- No:23238
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
It is not possible to add it. More Details >>
- No:23372
- Release Date:2018/09/12 15:12
-
About Low-voltage Power Distribution Products
SD-T12 to T32 and SD-N600, N800 type operation coil terminals have polarity. Connect terminal mumber A1 (+) to the positive and A2 (-) to the negative sid... More Details >>
- No:23271
- Release Date:2018/09/12 15:11
- Update:2021/04/09 16:21
-
About Low-voltage Power Distribution Products
It is a current value that can break ( turning contact "OFF") under theconditions specified in the standard. (In IEC, number of tests is 50 times) More Details >>
- No:23261
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
Since it is necessary to energize the pole containing a heater element of athermal load relay, you need to connect it to both side of 3 poles(Between 1/L1-2/... More Details >>
- No:23249
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
When carrying the rated current at ambient temperature of 40℃ (whencarrying the rated heater load), the maximum temparature of cooling finis approximately 100℃. More Details >>
- No:23358
- Release Date:2018/09/12 15:12
-
About Low-voltage Power Distribution Products
Since the control coil of DU-N type is AC operation DC excitation methodof an electromagnet type and it includes the surge suppresing function.Therefore, a s... More Details >>
- No:23353