The Earth Leakaga Circuit Breaker does not work since leakage current ofSSC is the current flowing from the main circuit element to the load sidewhen opening. More Details >>
- No:23338
- Release Date:2018/09/12 15:12
-
About Low-voltage Power Distribution Products
It is the maximum applicable load capacity at rated operational voltage. More Details >>
- No:23236
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
Since US-H* tyep is controlled by DC power supply (12 to 24 V DC), it cannot be operated with AC power supply. More Details >>
- No:23357
- Release Date:2018/09/12 15:12
-
About Low-voltage Power Distribution Products
It is coil capacity (power consumption) when a control coil is energizedand a contact is closed. More Details >>
- No:23333
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
The minimum applicable load voltage and current are as follows. Contactreliability is indicated by fault rate λ60 (Number of faults / Operatingcycles per one... More Details >>
- No:23290
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
It is a current value that can break ( turning contact "OFF") under theconditions specified in the standard. (In IEC, number of tests is 50 times) More Details >>
- No:23261
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
It is also called jogging and it means frequently opening and closing thestarting currents such as small movement of a motor. More Details >>
- No:23242
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
The faults of main circuit element in a solid state contactor happenbecause:1. Excessive overcurrent that is over permissible current flows due to loadcircui... More Details >>
- No:23258
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
When carrying the rated current at ambient temperature of 40℃, themaximum temparature of cooling fin is approximately 90℃. More Details >>
- No:23360
- Release Date:2018/09/12 15:12
-
About Low-voltage Power Distribution Products
The minimum applicable load is 20V, 3mA . Contact reliability is indicatedby fault rate λ60 (Number of fault / Operating cycles per one contact) atthe reliab... More Details >>
- No:23304
- Release Date:2018/09/12 15:11