- FAQ > Low-voltage Power Distribution Products > Contactors and Motor Starters > Motor Starters
FAQ
Keyword Search
FAQ within [ Motor Starters ]
-
About Low-voltage Power Distribution Products
It is the maximum voltage that opens the contact (turning contact "OFF")when removing the applied voltage of a control coil in a magneticcontactor. More Details >>
- No:23313
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
It is possible to replace it by user. More Details >>
- No:23321
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
It is a general starting method that applies full voltage to a motor in orderto start and stop. It is also called Full voltage starting. More Details >>
- No:23256
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
Reverse connection is possible (connection of load side terminal as powerside and power side terminal as load side). However, it is necessary toinstall a mag... More Details >>
- No:23286
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
It is not possible to produce them. More Details >>
- No:23363
- Release Date:2018/09/12 15:12
-
About Low-voltage Power Distribution Products
It is the limit of operating cycles that a magnetic contactor can be usedwithout any problems under the conditions specified in the standard. More Details >>
- No:23265
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
The current transformer in ET-N* type detects the main circuit current,deals with overcurrent protection, and protects the load equipment. Sincethe applicabl... More Details >>
- No:23272
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
It is utilization category specified in IEC 60947-4-1. AC-3 category is usedfor starting a motor or stopping during operation etc. More Details >>
- No:23241
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
You can make sure with a display window beside the adjustment knob ofthe thermal load relay. If green is displayed in the display window, it isreset state, a... More Details >>
- No:23251
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
It is necessary to change the wires connected by solder to the board of theDL circuit since the wire length is short. Therefore, it is not possible toconnect... More Details >>
- No:23299
- Release Date:2018/09/12 15:11
51-60 of Total 142