FAQ
FAQAbout Products
- FAQ > Low-voltage Power Distribution Products > Contactors and Motor Starters > Motor Starters
FAQ
Keyword Search
FAQ within [ Motor Starters ]
-
About Low-voltage Power Distribution Products
Inrush current does not flow since the full voltage directly applys theelectromagnet of SD-Q* and only resistance component of theelectromagnet limits the cu... More Details >>
- No:23277
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
There is no surge suppressor for a control coil. The control coil of S-T65 toS-N800 type has the AC operation DC excitation method and includes thesurge supp... More Details >>
- No:23276
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
These two different colors of the knob identify 2-element type and 3-element type of a thermal load relay. Gray: TH-* (Heater 2-element type)Orange: TH-*KP t... More Details >>
- No:23273
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
The current transformer in ET-N* type detects the main circuit current,deals with overcurrent protection, and protects the load equipment. Sincethe applicabl... More Details >>
- No:23272
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
For our reduced-voltage starter, when the starting time is over 15 sec,you need to review the selection of MCS and the wiring between MCD-MCS, and check whet... More Details >>
- No:23267
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
The main part of SRT(D)-NF type is a special product and different fromthe standard product relay (SR(D)-N type). Therefore, we do not providethe timer unit ... More Details >>
- No:23264
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
The temparature rise of a terminal connected by customer is designed tobe under 65℃ according to the standard. For our products, there is nospecification abo... More Details >>
- No:23259
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
The faults of main circuit element in a solid state contactor happenbecause:1. Excessive overcurrent that is over permissible current flows due to loadcircui... More Details >>
- No:23258
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
It is a current that can be energized for 8 hours without opening/closingthe magnetic contactor and in the state that the temperature rise value ofeach part ... More Details >>
- No:23255
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
You can make sure with a display window beside the adjustment knob ofthe thermal load relay. If green is displayed in the display window, it isreset state, a... More Details >>
- No:23251
- Release Date:2018/09/12 15:11
61-70 of Total 142