About Low-voltage Power Distribution Products
The fault detection contact of the cooling fan detects the temperature ofthe fin in the solid state contactor and operates when exceeding thespecified value.... More Details >>
- No:23301
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
It is a coil that opens/closes a magnetic contactor by magnetizing(applying suction force) or demagnetizing an electromagnet core. More Details >>
- No:23303
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
The minimum applicable load is 20V, 3mA . Contact reliability is indicatedby fault rate λ60 (Number of fault / Operating cycles per one contact) atthe reliab... More Details >>
- No:23304
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
In the withstand voltage test, 2500V is applied for 1 min. The appliedlocation is as follows.1. Between the conductive part and the grounded metal part, and ... More Details >>
- No:23305
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
You need to connect the two terminal of No.15, 16 or 18 terminal to theload side of the contactor. (The remaining terminal is unnecessary toconnect.) More Details >>
- No:23307
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
This is because the delay time becomes shorter since the rebound force ofa spring against the suction force of a magnetic contactor increases if thecontact "... More Details >>
- No:23309
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
It is a film capacitor, not electrolytic capacitor. More Details >>
- No:23316
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
By opening/closing load with SSC of the zero-voltage triggering method, itreduces noise voltage when closing. More Details >>
- No:23323
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
Since the permanent magnet is used for the electromagnet part of SD-Qtype, it is necessary to match its polarity with the polarity of the controlcoil. More Details >>
- No:23324
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
It is coil capacity (power consumption) when a control coil is energizedand a contact is closed. More Details >>