FAQ


FAQAbout Products
- FAQ > Low-voltage Power Distribution Products > Contactors and Motor Starters > Motor Starters
FAQ
Keyword Search
FAQ within [ Motor Starters ]
-
About Low-voltage Power Distribution Products
Delay-open type magnetic starter (MSO-T*DL and MSO-N*DL type) andmagnetic contactor (S-T*DL and S-N*DL type) have electrolyticcapacitors. Other types do not ... More Details >>
- No:23331
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
It is possible to open/close three-phase load by opening/closing two poleswith three-phase circuit. If US-H opens/closes two poles and theremaining pole is s... More Details >>
- No:23367
- Release Date:2018/09/12 15:12
-
About Low-voltage Power Distribution Products
A thermal load relay is intended for burnout protection of three-phasesquirrel cage motor. When direct current is applied to the thermal loadrelay, the opera... More Details >>
- No:23281
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
At ambient temperature 40℃, the rated voltage (frequency) is applied to acontrol coil, and after temperature rise and saturation, it can operatewithout any t... More Details >>
- No:23298
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
It is a coil that opens/closes a magnetic contactor by magnetizing(applying suction force) or demagnetizing an electromagnet core. More Details >>
- No:23303
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
For US-N5/8SS(TE) and US-N70/80NS(TE), the rated impulse withstandvoltage is 4kV. For US-N20 to 50(TE) and US-NH70/NH80NS(TE), the ratedimpulse withstand vol... More Details >>
- No:23322
- Release Date:2018/09/12 15:11
- Update:2018/09/26 09:22
-
About Low-voltage Power Distribution Products
In the withstand voltage test, AC 1500V is applied for 1 min However, apressurizing part is only between a terminal part (conductive part) and amounting surf... More Details >>
- No:23377
- Release Date:2018/09/12 15:12
-
About Low-voltage Power Distribution Products
In the withstand voltage test, 2500V is applied for 1 min. The appliedlocation is as follows.1. Between the conductive part and the grounded metal part, and ... More Details >>
- No:23305
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
We can not produce it. More Details >>
- No:23332
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
Since the control coil of DU-N type is AC operation DC excitation methodof an electromagnet type and it includes the surge suppresing function.Therefore, a s... More Details >>
- No:23353
- Release Date:2018/09/12 15:12
81-90 of Total 142