FAQ


FAQAbout Products
- FAQ > Low-voltage Power Distribution Products > Contactors and Motor Starters > Motor Starters
FAQ
Keyword Search
FAQ within [ Motor Starters ]
-
About Low-voltage Power Distribution Products
The fault detection contact of the cooling fan detects the temperature ofthe fin in the solid state contactor and operates when exceeding thespecified value.... More Details >>
- No:23301
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
It is a combination of a magnetic contactor and a thermal overload relay. More Details >>
- No:23296
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
Since US-N/K/H type is a solid state contactor having zero-voltage-triggering method, surge voltage does not occur due to opening/closing amain circuit. More... More Details >>
- No:23291
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
In the case of DC, since the load current breaking is more difficultcompared to AC, permanent magnet is provided at each main contactpoint and the arc is dri... More Details >>
- No:23289
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
At ambient temperature 40℃, the rated voltage (frequency) is applied tothe control coil, and after temperature rise and saturation, it can operatewithout any... More Details >>
- No:23284
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
You can install it as follows.1. Regular installation of the power supply side terminal as the upper partand the load side terminal as the lower side2. Incli... More Details >>
- No:23283
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
It is a contactor that opens/close a main contact part by the force ofelectromagnet (coil). More Details >>
- No:23279
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
It is a general starting method that applies full voltage to a motor in orderto start and stop. It is also called Full voltage starting. More Details >>
- No:23256
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
When installing a thermal load relay in the delta phase and detectingphase current, you select a heater designation that can be set to 1 / √ 3times of the mo... More Details >>
- No:23240
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
In our 3-contactor type star-delta starter (EYD), in order to eliminate thebreaking duty of the star contactor (MCS), the main contactor (MCM)break the star-... More Details >>
- No:23239
- Release Date:2018/09/12 15:11
81-90 of Total 142