The leakage current breaker trips.
Cause:Incorrect breaker selection(current capacity/drive purpose, etc.). Leakage current due to electrically conductive foreign matters(oil/moisture) getting... More Details >>
- No:23173
- Release Date:2018/09/07 16:09
- Category: Vertical type robot , Horizontal type robot , Ceiling mounted, holizontal type robot
-
Cause:Deterioration in the reducer oil seal. Too much grease was applied. A grease other than the specified grease was applied. Excess grease left on the uni... More Details >>
- No:23174
- Release Date:2018/09/07 16:09
- Category: Vertical type robot , Horizontal type robot , Ceiling mounted, holizontal type robot
-
Brake is not working properly.
Cause:[Occurs only when operating manually]•T/B operation error.[Occurs when operating manually and automatically]•Faulty connection of the cables that run b... More Details >>
- No:23178
- Release Date:2018/09/07 16:09
- Category: Vertical type robot , Horizontal type robot , Ceiling mounted, holizontal type robot
-
Brake is not working properly.
Cause:[Occurs only when operating manually]•T/B operation error.•The enabling device input is open.[Occurs when operating manually and automatically]•Faulty ... More Details >>
- No:23183
- Release Date:2018/09/07 16:09
- Category: Vertical type robot , Horizontal type robot , Ceiling mounted, holizontal type robot
-
The servo-on cannot be performed.
Cause:A servo OFF signal(SRVOFF)is being input from an external source. The operating right is not given.(IOENA parameters settings/exclusive input and outpu... More Details >>
- No:23170
- Release Date:2018/09/07 16:09
- Category: Vertical type robot , Horizontal type robot , Ceiling mounted, holizontal type robot
-
Cause:Program error (arithmetic processing, etc.). Teaching operation error. Peripheral equipment is offset. There is a setting error in the origin position ... More Details >>
- No:23172
- Release Date:2018/09/07 16:09
- Category: Vertical type robot , Horizontal type robot , Ceiling mounted, holizontal type robot
-
Operation panel does not display anything.
Cause:CPU has not started up properly.There is no power supply.An instantaneous power cut exceeding the specification level may have occurred.Measures:Check ... More Details >>
- No:23181
- Release Date:2018/09/07 16:09
- Category: Vertical type robot , Horizontal type robot , Ceiling mounted, holizontal type robot
-
The tip of the robot is vibrating.
Cause:The load conditions exceed the specified values(mass, inertia).The load condition settings are not suitable(HNDDAT and WRKDAT settings are not consiste... More Details >>
- No:23169
- Release Date:2018/09/07 16:09
- Category: Vertical type robot , Horizontal type robot , Ceiling mounted, holizontal type robot