  • The T/B does not display anything.

    Cause:The fuse (4A fuse) installed at the bottom of the 24 V power supply circuit in the controller may have blown out.For the fuse blowout, the emergency st... More Details >>

    • No:23184
    • Release Date:2018/09/07 16:09
  • An unusual noise can be heard (from the robot arm).

    Cause:Unusual noises can be caused by friction between movable parts, deformed parts, foreign matters getting inside, and defects in belt tension.An unusual ... More Details >>

    • No:23167
    • Release Date:2018/09/07 16:09
  • The servo-on cannot be performed.

    Cause:A servo OFF signal(SRVOFF)is being input from an external source. The operating right is not given.(IOENA parameters settings/exclusive input and outpu... More Details >>

    • No:23170
    • Release Date:2018/09/07 16:09
  • The leakage current breaker trips.

    Cause:Incorrect breaker selection(current capacity/drive purpose, etc.). Leakage current due to electrically conductive foreign matters(oil/moisture) getting... More Details >>

    • No:23173
    • Release Date:2018/09/07 16:09
  • Operation panel does not display anything.

    Cause:CPU has not started up properly.There is no power supply.An instantaneous power cut exceeding the specification level may have occurred.Measures:Check ... More Details >>

    • No:23181
    • Release Date:2018/09/07 16:09
  • Brake is not working properly.

    Cause:[Occurs only when operating manually]•T/B operation error.[Occurs when operating manually and automatically]•Faulty connection of the cables that run b... More Details >>

    • No:23178
    • Release Date:2018/09/07 16:09
  • Brake is not working properly.

    Cause:[Occurs only when operating manually]•T/B operation error.•The enabling device input is open.[Occurs when operating manually and automatically]•Faulty ... More Details >>

    • No:23183
    • Release Date:2018/09/07 16:09
  • The tip of the robot is vibrating.

    Cause:The load conditions exceed the specified values(mass, inertia).The load condition settings are not suitable(HNDDAT and WRKDAT settings are not consiste... More Details >>

    • No:23169
    • Release Date:2018/09/07 16:09