Breaker trips/overcurrent error occurs.
Cause:Deterioration in the packing. Scaling on the packing. Using a highly permeable cutting oil. An environment that exceeds the IP functionality. Measures:... More Details >>
- No:23175
- Release Date:2018/09/07 16:09
-
Cause:The Ethernet cable is not connected surely. There are the device etc. which cause the noise and the noise has applied to the Ethernet cable. Measures:C... More Details >>
- No:23179
- Release Date:2018/09/07 16:09
-
An unusual noise can be heard (from RC).
Cause:A noise is made as the internally mounted fan and its casing resonate. A noise is made by the fan catching internal wiring.Measures:Check the state of ... More Details >>
- No:23168
- Release Date:2018/09/07 16:09
-
The hand does not move properly (air hand).
Cause:An air leak/break in the piping. The solenoid bulb has failed. Wire breakage on the hand signal line. Hand signal line short circuitThe hand IF card ha... More Details >>
- No:23176
- Release Date:2018/09/07 16:09
-
The hand does not move properly (Electric operated hand).
Cause:Wire breakage on the hand signal line. The electronic hand controller(manufactured by TAIYO Ltd.) has failed. Faulty connection in the cables that run ... More Details >>
- No:23177
- Release Date:2018/09/07 16:09
-
Operation panel does not display anything.
Cause:CPU has not started up properly.There is no power supply.An instantaneous power cut exceeding the specification level may have occurred.Measures:Check ... More Details >>
- No:23181
- Release Date:2018/09/07 16:09
-
Brake is not working properly.
Cause:[Occurs only when operating manually]•T/B operation error.•The enabling device input is open.[Occurs when operating manually and automatically]•Faulty ... More Details >>
- No:23183
- Release Date:2018/09/07 16:09
-
The tip of the robot is vibrating.
Cause:The load conditions exceed the specified values(mass, inertia).The load condition settings are not suitable(HNDDAT and WRKDAT settings are not consiste... More Details >>
- No:23169
- Release Date:2018/09/07 16:09
-
The leakage current breaker trips.
Cause:Incorrect breaker selection(current capacity/drive purpose, etc.). Leakage current due to electrically conductive foreign matters(oil/moisture) getting... More Details >>
- No:23173
- Release Date:2018/09/07 16:09
-
The T/B does not display anything.
Cause:The fuse installed in the controller may have blown out. For the fuse blowout, there may be a ground fault or short circuit in the T/B cable. The T/B m... More Details >>
- No:23180
- Release Date:2018/09/07 16:09