FAQ


FAQAbout Products

FAQ
Keyword Search
FAQ within [ GT27 ]
-
Use of commercially available USB memories for the GOT2000 series
You can use commercially available USB memories for the GOT2000 series. Note that we do not guarantee the operation when commercially available USB memories ... More Details >>
- No:23493
- Release Date:2018/09/14 15:06
-
Use of commercially available SD memory cards for the GOT2000 series
You can use commercially available SD memory cards for the GOT2000 series. Note that we do not guarantee the operation when commercially available USB memori... More Details >>
- No:23494
- Release Date:2018/09/14 15:06
-
Transferring data between a personal computer and a GOT via a PLC
The GOT screen data can be read and written from and to a personal computer via a PLC. Note that the following items have restrictions. ・ Connection typ... More Details >>
- No:23497
- Release Date:2018/09/14 15:06
- Update:2018/09/26 15:33
-
Operating by touching the screen with gloves on
You can operate the GOT2000 series by touching the screen with cotton or rubber gloves on since the GOT2000 series uses resistive touch panel. More Details >>
- No:23502
- Release Date:2018/09/14 15:06
-
Checking the simultaneous 2-point press switches placed on the screen design software
You cannot check the two switches placed at a location where the simultaneous 2-point press is invalid on the screen design software. When creating a screen ... More Details >>
- No:23503
- Release Date:2018/09/14 15:06
- Update:2018/09/25 17:28
-
Compatibility of communication cables for the GOT1000 series
Only when the connectors have the same number of pins, shape, and communication format, the communication cable for the GOT1000 series can be used for the GO... More Details >>
- No:23422
- Release Date:2018/09/14 15:06
- Update:2018/09/26 16:38
-
Asynchronous screen display with the VNC server function
Different screens cannot be displayed on the GOT screen (VNC server) and VNC client screen with the VNC server function. To display different screens, use t... More Details >>
- No:23425
- Release Date:2018/09/14 15:06
- Update:2020/01/07 15:46
-
Trial use of the remote personal computer operation function (Ethernet)
You can try the remote personal computer operation function (Ethernet) without registering the license number. You can try the remote personal computer oper... More Details >>
- No:23431
- Release Date:2018/09/14 15:06
- Update:2018/09/26 16:45
-
◆ For GT Designer3 (GOT2000) Version1.108N or later The MES interface function can be used in the GOT2000 series as well. However, the license of the MES... More Details >>
- No:23434
- Release Date:2018/09/14 15:06
- Update:2018/09/26 16:48
-
Connecting FA devices through the wireless LAN communication unit (GT25-WLAN)
An FA device such as a PLC and the GOT cannot be connected through a wireless LAN by using the wireless LAN communication unit (GT25-WLAN). More Details >>
- No:23439
- Release Date:2018/09/14 15:06
- Update:2018/09/26 16:53
41-50 of Total 98