Low-voltage Power Distribution Products
FAQ within [ Low-voltage Power Distribution Products ]
-
Recommended update period (ME96SS series).
The expected lifetime is 10 years. Is recommended to replace the device every 10 year. However the environment of installed location, such as temperature ... More Details >>
- No:22154
- Release Date:2018/08/27 16:41
- Update:2020/04/10 16:02
- Category: Electrical Indicators
-
The control power supply of the earth leakage detection circuit is taken from the inside of Earth Leakage Circuit Breaker. If used on the secondary side of t... More Details >>
- No:22372
- Release Date:2018/08/31 14:33
- Category: Earth Leakage Circuit Breakers
-
It means a space between the edge of a exhaust port and panel component ( such as wall or duct) of a circuit breaker. The arc space is needed for smoothly di... More Details >>
- No:22373
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
-
How to install cassette type accessories
A circuit breaker shall be Trip position when installing Cassette type accessory. The breaker may be damaged if installing in "ON" or "OFF" position. Moreove... More Details >>
- No:22422
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
-
Default setting of electronic breakers
Each setting knob of the overcurrent trip characteristic is set to the maximum value and then shipped if not specified. However, only the pre-alarm is set to... More Details >>
- No:22438
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
-
About Low-voltage Power Distribution Products
SD-T12 to T32 and SD-N600, N800 type operation coil terminals have polarity. Connect terminal mumber A1 (+) to the positive and A2 (-) to the negative sid... More Details >>
- No:23271
- Release Date:2018/09/12 15:11
- Update:2021/04/09 16:21
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
You must not desassemble it since mechanical latched type has beenadjusted and tested at our factory. More Details >>
- No:23325
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
Read data stored by the built-in logging function
The stored data can be read from MODBUS RTU communication. To use this function, MODBUS RTU communication is required. It is not available with MOD... More Details >>
- No:37808
- Release Date:2020/04/10 15:09
- Category: Electrical Indicators
-
Availability of an option for ME96NS Series (ME96SS series).
An option for ME96NS series can NOT be installed to the main body of ME96SS series. An option for ME96SS series can NOT be installed to the main body of ME9... More Details >>
- No:22162
- Release Date:2018/08/27 16:41
- Category: Electrical Indicators
-
Measurement value different from other measuring instrument (ME96SS series).
In general, in case of measurement by the average method, the waveform including harmonics cause large error. This model uses the RMS value method and measu... More Details >>
- No:22177
- Release Date:2018/08/27 16:41
- Update:2020/04/10 16:54
- Category: Electrical Indicators
101-110 of Total 322