It is the number that can be opened/closed per hour under the conditions specified in the standard. More Details >>
- No:22436
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
-
"b contact" is normally closed contact, and It is also called "NC (Normally Closed) contact". More Details >>
- No:22435
- Release Date:2018/08/31 14:33
- Category: Accessories and Related Components
-
There are Fixed type and Drawout type. More Details >>
- No:22430
- Release Date:2018/08/31 14:33
- Category: Air Circuit Breakers
-
CP30-BA AL and AX switch micro-load can be provided. And the number of installation is same as standard AL and AX switch. However, if multiple AL and AX are ... More Details >>
- No:22427
- Release Date:2018/08/31 14:33
- Category: Circuit Breakers for Equipment
-
Large electromagnetic force will be generated between conductors/wires due to fault currents. To prevent deformation and breakage of circuit breakers and con... More Details >>
- No:22424
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
-
Shunt Trip for CP30-BA can be provided. However, the pole of that with Shunt Trip is "Relay type" without overcurrent tripping element. Internal circuit is "... More Details >>
- No:22423
- Release Date:2018/08/31 14:33
- Category: Circuit Breakers for Equipment
-
The applicable voltage is 440V or less. Moreover, High-speed type can be used from 85 to 484V, and Time-delay type can be used from 170 to 484V. More Details >>
- No:22421
- Release Date:2018/08/31 14:33
- Category: Earth Leakage Circuit Breakers
-
ACB add earth leakage protection
When earth leakage current protection module (ER) is attached, it is possible to protect against earth leakage current. "Trip" or "Alarm signal output" can b... More Details >>
- No:22420
- Release Date:2018/08/31 14:33
- Category: Air Circuit Breakers
-
ACB combination Ground fault protection and earth leakage protection
It is not possible to combine them at the same time. You need to choose one of them. More Details >>
- No:22419
- Release Date:2018/08/31 14:33
- Category: Air Circuit Breakers
-
Change Electronic relay characteristics when it is energized
Only electricians who have enough technical knowledge should change the setting of overcurrent tripping and earth leakage tripping characteristics. Moreover,... More Details >>
- No:22409
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers