Low-voltage Power Distribution Products
FAQ within [ Low-voltage Power Distribution Products ]
-
Inst tripping current value of AC/DC common breaker
At time-delay tripping zone, it operates with bimetal, therefore the characteristics of AC and DC should be same if the effective values of them are same. Ho... More Details >>
- No:22392
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
-
Earth Leakage Circuit Breaker and Earth Leakage Relay operate at higher than 50% but not exceeding 100% of the rated residual operating current IΔn. The eart... More Details >>
- No:22364
- Release Date:2018/08/31 14:33
- Category: Earth Leakage Circuit Breakers
-
It is a tripping zone which instantly trips, when significantly overcurrent such as short-circuit currents flow. More Details >>
- No:22363
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
-
It is a method which breaks short circuit current with both upstream and downstream circuit breakers. For example, in the case that short circuit current at ... More Details >>
- No:22357
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
-
Concurrent-use of MODBUS RTU and MODBUS TCP (ME96SS series).
MODBUS RTU communication and MODBUS TCP communication can be used at the same time. More Details >>
- No:22188
- Release Date:2018/08/27 16:41
- Category: Electrical Indicators
-
Disable an alarm for motor starting current (ME96SS series).
This model has “Motor Starting Current Mask Function”. This function stops the alarm output and updating of the maximum values during the setting time when a... More Details >>
- No:22175
- Release Date:2018/08/27 16:41
- Update:2020/04/10 16:51
- Category: Electrical Indicators
-
Compensation for power failure (ME96SS series).
The setting data are memorized in nonvolatile memory, so the data is not deleted at the time of a power interruption. (The main body does not use a battery.)... More Details >>
- No:22163
- Release Date:2018/08/27 16:41
- Update:2020/04/10 16:16
- Category: Electrical Indicators
-
Measurable minimum load (ME96SS series).
In case of the input current of less than 0.005 A, the measurement values are as follows: Current: 0 A, Power supply: 0 W, Reactive power: 0 var, Apparent... More Details >>
- No:22155
- Release Date:2018/08/27 16:41
- Update:2020/04/10 16:04
- Category: Electrical Indicators
-
MCB can be used at 85% or less relative humidity and no condensation. More Details >>
- No:24822
- Release Date:2019/04/09 15:11
- Category: Miniature Circuit Breakers
-
Plug-in type NF1600-SEW produced
It is impossible. More Details >>
- No:24817
- Release Date:2019/04/09 15:16
- Category: Molded Case Circuit Breakers
141-150 of Total 322