Low-voltage Power Distribution Products
FAQ within [ Low-voltage Power Distribution Products ]
-
The push button is used for testing whether it definitely trips when an earth leakage current occurs. At this test, a Leakage Display button will be come out... More Details >>
- No:22347
- Release Date:2018/08/31 14:33
- Category: Earth Leakage Circuit Breakers
-
Setting for communication (ME96SS series).
1) For the main body of ME96: Please set the following values on the “Set-up menu 2”. In case of MODBUS RTU Set-up menu No. Setti... More Details >>
- No:22181
- Release Date:2018/08/27 16:41
- Update:2020/04/10 17:05
- Category: Electrical Indicators
-
Display upon upper/lower limit alarm (ME96SS series).
The measurement elements, including the digital indication, the unit indication and the phase indication, flash. And the “ALARM” indication and the “HI” in... More Details >>
- No:22169
- Release Date:2018/08/27 16:41
- Update:2020/04/10 16:36
- Category: Electrical Indicators
-
Set values cannot be changed on the setting mode (ME96SS series).
When[SET] is flashing, the “Setting Value Confirmation Mode” is selected. In this case, the set values cannot be changed. Pressing the buttons of the “Set” ... More Details >>
- No:22168
- Release Date:2018/08/27 16:41
- Update:2020/04/10 16:22
- Category: Electrical Indicators
-
Measurable minimum voltage (ME96SS series).
In case of the input voltage of less than 11 V, the measurement values are as follows: Voltage: 0 V,Power supply: 0 W, Reactive power: 0 var, Apparent pow... More Details >>
- No:22156
- Release Date:2018/08/27 16:41
- Update:2020/04/10 16:08
- Category: Electrical Indicators
-
Check the measurement values using MODBUS RTU communication
It is possible to check them using the Data Acquisition Software EMU4-SW1. It is available for download without payment from the following Web site. ... More Details >>
- No:37812
- Release Date:2020/04/10 15:10
- Category: Electrical Indicators
-
3P MCCB in 1-phase 2-wire circuit
It is possible. Refer to the figure for connection as below. More Details >>
- No:24811
- Release Date:2019/04/09 15:18
- Category: Molded Case Circuit Breakers
-
About Low-voltage Power Distribution Products
The permissible variation range of frequency (short time variation) is ±5%. More Details >>
- No:23371
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is not possible to replace it since we do not sell it as a unit. More Details >>
- No:23369
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
US-N* type is controlled by DC power supply (12 to 24 VDC). However,UA-DR1/UA-SH1 driving-unit of option unit make it possible to control byAC power supply (... More Details >>
- No:23359
- Release Date:2018/09/12 15:12
- Category: Motor Starters