Large electromagnetic force will be generated between conductors/wires due to fault currents. To prevent deformation and breakage of circuit breakers and con... More Details >>
- No:22424
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
-
It is possible to produce micro-load AL and AX switch for MCCBs/ELCBs. However, if you need the products compatible with the standards (CE marking product an... More Details >>
- No:22413
- Release Date:2018/08/31 14:33
- Category: Accessories and Related Components
-
It is overcurrent tripping characteristic zone which exceeds the rated current and does not exceed short time tripping zone (If without short time tripping ,... More Details >>
- No:22384
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
-
It means that it does not interfere with tripping operation even if a handle is held at "ON" position. (It trips when an overcurrent flows even if a handle i... More Details >>
- No:22378
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
-
How to connect to 2-pole breaker
(1) When "N" is marked on the breaker,connect the N phase wire as marked. (2) When "N" is not marked on the breaker, N phase wire can be connected to eith... More Details >>
- No:37700
- Release Date:2020/01/17 08:58
- Category: Molded Case Circuit Breakers
-
About Low-voltage Power Distribution Products
It is possible to produce, however, it may cause unnecessary trippingwhen using inching. More Details >>
- No:23373
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
The head-on type of UN-AX 2 and AX 4 type can be installed. The side-onunit of UN-AX 11 type can not be installed. More Details >>
- No:23342
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
Since the permanent magnet is used for the electromagnet part of SD-Qtype, it is necessary to match its polarity with the polarity of the controlcoil. More Details >>
- No:23324
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is possible to replace it by user. More Details >>
- No:23321
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
You need to connect the two terminal of No.15, 16 or 18 terminal to theload side of the contactor. (The remaining terminal is unnecessary toconnect.) More Details >>