FAQ


FAQAbout Products
FAQ
Keyword Search
Low-voltage Power Distribution Products
FAQ within [ Low-voltage Power Distribution Products ]
-
About Low-voltage Power Distribution Products
For US-N/K/H type, since current is opened/closed by semiconductorelement, there is no lifetime related to operating cycles, but werecommend to replace in 10... More Details >>
- No:23274
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
The contacts are closed by electrical (closing coil) or mechanical operationand even if the operating force is removed, the closed state is maintainedby the ... More Details >>
- No:23253
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
The applicable voltage is 440V or less. Moreover, High-speed type can be used from 85 to 484V, and Time-delay type can be used from 170 to 484V. More Details >>
- No:22421
- Release Date:2018/08/31 14:33
- Category: Earth Leakage Circuit Breakers
-
It is possible to modify to Rear-connection type by Mitsubishi's certified staff. More Details >>
- No:22399
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
-
High-speed residual operate CBR
It is Earth Leakage Circuit Breaker that the earth leakage trip operating time at the rated residual operating current (IΔn) is within 0.1 sec, and the earth... More Details >>
- No:22380
- Release Date:2018/08/31 14:33
- Category: Earth Leakage Circuit Breakers
-
It may not trip a fault current or degrade insulation after tripping. When you connect the device in reverse, you must select a reverse-connectable model. More Details >>
- No:22345
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
-
A circuit breaker must have interrupting ratings. These are classified as rated short-circuit breaking capacities in IEC 60947-2.e rated ultimate short-circu... More Details >>
- No:22341
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
-
Register address for active energy monitors in the MODBUS RTU communication (ME96SS series).
The acquired digit length of “1280”, “1281” and “1304” varies with the full load power. The acquired digit length of “1304” is 6-digit. Each of “1280” and... More Details >>
- No:22184
- Release Date:2018/08/27 16:41
- Update:2020/04/10 17:18
- Category: Electrical Indicators
-
Compensation for power failure (ME96SS series).
The setting data are memorized in nonvolatile memory, so the data is not deleted at the time of a power interruption. (The main body does not use a battery.)... More Details >>
- No:22163
- Release Date:2018/08/27 16:41
- Update:2020/04/10 16:16
- Category: Electrical Indicators
-
Measurable minimum load (ME96SS series).
In case of the input current of less than 0.005 A, the measurement values are as follows: Current: 0 A, Power supply: 0 W, Reactive power: 0 var, Apparent... More Details >>
- No:22155
- Release Date:2018/08/27 16:41
- Update:2020/04/10 16:04
- Category: Electrical Indicators
211-220 of Total 322