A thermal load relay is intended for burnout protection of three-phasesquirrel cage motor. When direct current is applied to the thermal loadrelay, the opera... More Details >>
- No:23281
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
There is no surge suppressor for a control coil. The control coil of S-T65 toS-N800 type has the AC operation DC excitation method and includes thesurge supp... More Details >>
- No:23276
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
For US-N/K/H type, since current is opened/closed by semiconductorelement, there is no lifetime related to operating cycles, but werecommend to replace in 10... More Details >>
- No:23274
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
A thermal load relay is set as full-load current of a motor. However, ifambient temperature is significantly different from 20℃ or the connectingwire is diff... More Details >>
- No:23238
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
When Power-Fuse (PF) is used as a high-voltage side protection device, coordination with MCCBs on the secondary side shall be achieved. Therefore, MCCB has l... More Details >>
- No:22403
- Release Date:2018/08/31 14:33
- Category: Circuit Breakers for Use in Particular Applications
-
How to select at Inverter circuit
Basically you have to consider the effect of harmonic waves, but there are two ways as below. 1. Refer to the recommended rated current by inverter manufactu... More Details >>
- No:22360
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
-
Rating of a circuit breaker for transformers primary protection
When making a transformer to energize, a large inrush current may flow. The circuit breaker is therefore required to prevent unwanted trip. The selection of ... More Details >>
- No:22343
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
-
About Low-voltage Power Distribution Products
We do not provide it. More Details >>
- No:23350
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
Time rating is 60sec and the rest time is for 2 hours. More Details >>
- No:23308
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
For our reduced-voltage starter, when the starting time is over 15 sec,you need to review the selection of MCS and the wiring between MCD-MCS, and check whet... More Details >>
- No:23267
- Release Date:2018/09/12 15:11
- Category: Motor Starters