About Low-voltage Power Distribution Products
It is possible to open/close three-phase load by opening/closing two poleswith three-phase circuit. If US-H opens/closes two poles and theremaining pole is s... More Details >>
- No:23367
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
There is a terminal cover for it. ( In MSOD-Q* type magnetic starter, thereis no terminal cover for the thermal load relay although the contactor parthas a t... More Details >>
- No:23330
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
You can install it as follows.1. Regular installation of the power supply side terminal as the upper partand the load side terminal as the lower part2. An in... More Details >>
- No:23326
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It means the rated operating voltage (nominal voltage) range andfrequency (when AC operation) of a control coil. More Details >>
- No:23266
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is a circuit flowing small current (A few dozen Ma to several A) such ascontrol coil and indicator light circuit of magnetic contactor and itopens/closes ... More Details >>
- No:23257
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
The interlock allows only one magnetic starter to be turned"ON" and notanother opposit side magnetic starter in the case that two magneticstarters must not b... More Details >>
- No:23244
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
It is not possible to use standard AE-SW in DC circuit. Special DC use AE-SW is provided if specified. More Details >>
- No:22446
- Release Date:2018/08/31 14:33
- Category: Air Circuit Breakers
-
This contact(SBC) is used to auxiliary switch(AXb) contact. When Drawout type ACB is moved from "test" position to "disconnect" position, AXb contact will b... More Details >>
- No:22416
- Release Date:2018/08/31 14:33
- Category: Air Circuit Breakers
-
When Power-Fuse (PF) is used as a high-voltage side protection device, coordination with MCCBs on the secondary side shall be achieved. Therefore, MCCB has l... More Details >>
- No:22403
- Release Date:2018/08/31 14:33
- Category: Circuit Breakers for Use in Particular Applications
-
The push button is used for testing whether it definitely trips when an earth leakage current occurs. At this test, a Leakage Display button will be come out... More Details >>
- No:22347
- Release Date:2018/08/31 14:33
- Category: Earth Leakage Circuit Breakers