Almost MCCBs can be connected n reverse. Check the item column of specification table "reverse connection" in the catalog. If it says "Possible", MCCB can be... More Details >>
- No:22442
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
-
About Low-voltage Power Distribution Products
US-N* type can be used for AC power supply motor, heater, lighting loadand capacitor load etc. More Details >>
- No:23365
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
Acquired values through MODBUS RTU.
The acquired value by communication should be multiplied by the multiplying factor to change into the measurement value. Please refer to Section 7.3 of ... More Details >>
- No:22183
- Release Date:2018/08/27 16:41
- Update:2020/04/13 09:13
- Category: Electrical Indicators
-
Please check the register addresses. The register address for the present value of the power factor of each phase is “0789”. There are the register addre... More Details >>
- No:22191
- Release Date:2018/08/27 16:41
- Category: Electrical Indicators
-
AC Breakers used at DC circuit
It is not possible to use a circuit breaker for AC in DC circuit. Since the Arc-Extinguishing Device structure of circuit breaker for DC is different from th... More Details >>
- No:22381
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
-
"b contact" is normally closed contact, and It is also called "NC (Normally Closed) contact". More Details >>
- No:22435
- Release Date:2018/08/31 14:33
- Category: Accessories and Related Components
-
About Low-voltage Power Distribution Products
These two different colors of the knob identify 2-element type and 3-element type of a thermal load relay. Gray: TH-* (Heater 2-element type)Orange: TH-*KP t... More Details >>
- No:23273
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
ACB How to check the operating characteristic
Y-2005 type field test equipment (it is sold separately) enable to check the operating characteristic easily. The test is conducted by connecting the test te... More Details >>
- No:22429
- Release Date:2018/08/31 14:33
- Category: Air Circuit Breakers
-
About Low-voltage Power Distribution Products
The consumption VA of a control circuit is 7VA for AC 100V product and14VA for AC 200 V product. More Details >>
- No:23348
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
Change Electronic relay characteristics when it is energized
Only electricians who have enough technical knowledge should change the setting of overcurrent tripping and earth leakage tripping characteristics. Moreover,... More Details >>
- No:22409
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers