FAQ


FAQAbout Products

FAQ
Keyword Search
Low-voltage Power Distribution Products
FAQ within [ Low-voltage Power Distribution Products ]
-
In order to prevent breakdowns and human injuries, it is necessary to select a control device having protection structure suitable for each purpose. The prot... More Details >>
- No:22443
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
-
About Low-voltage Power Distribution Products
The withstand voltage of US-N5SS, US-N8SS, US-N70NS and US-N80NStype is 2kV. The withstand voltage of US-N20 to 50 type is 2.5kV. Theapplied points are as fo... More Details >>
- No:23351
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is not possible to replace it since we do not sell it as a unit. More Details >>
- No:23369
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
Setting change operation while power is on
It is forbidden to change the characteristic when the breaker ON. Over current trip and earth leakage trip characteristics should be changed by a person with... More Details >>
- No:37699
- Release Date:2020/01/18 09:58
- Category: Molded Case Circuit Breakers , Air Circuit Breakers
-
Rating of a circuit breaker for transformers primary protection
When making a transformer to energize, a large inrush current may flow. The circuit breaker is therefore required to prevent unwanted trip. The selection of ... More Details >>
- No:22343
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
-
Use with 24V, 0.5A or more for AC and DC in normal use. If the breakers are used less than 24V, use with 6V, 1A or more. Moreover, regular inspection of is ... More Details >>
- No:22401
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
-
About Low-voltage Power Distribution Products
It is a circuit flowing large current (several A to approximately 1000A)such as a motor and a lighting circuit, and a main contact (Betweenterminal number 1/... More Details >>
- No:23260
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
If both of a closing coil and a tripping coil are continued to excite at thesame time, it will result in coil burnout. You need to design a system thatdoes n... More Details >>
- No:23282
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is possible to produce with the coil designation of less than AC 230V andDC 220V. Please add " SA" at the end of the type name. More Details >>
- No:23319
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
Since the permanent magnet is used for the electromagnet part of SD-Qtype, it is necessary to match its polarity with the polarity of the controlcoil. More Details >>
- No:23324
- Release Date:2018/09/12 15:11
- Category: Motor Starters
261-270 of Total 322