FAQ


FAQAbout Products

FAQ
Keyword Search
Low-voltage Power Distribution Products
FAQ within [ Low-voltage Power Distribution Products ]
-
About Low-voltage Power Distribution Products
1E is a motor protection relay against overload and constraint such as athermal load relay and an electronic motor protection relay. 2E is a motorprotection ... More Details >>
- No:23245
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
The interlock allows only one magnetic starter to be turned"ON" and notanother opposit side magnetic starter in the case that two magneticstarters must not b... More Details >>
- No:23244
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
Cold start operating characteristic is the operating time from flowingcurrents to operating while a heater temparature of a thermal load relay isthe same as ... More Details >>
- No:23243
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
When installing a thermal load relay in the delta phase and detectingphase current, you select a heater designation that can be set to 1 / √ 3times of the mo... More Details >>
- No:23240
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
In our 3-contactor type star-delta starter (EYD), in order to eliminate thebreaking duty of the star contactor (MCS), the main contactor (MCM)break the star-... More Details >>
- No:23239
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is a starting method that motor winding is star-connected and startingcurrent is set as one-third of direct-on-line and then it is delta-connectedafter ac... More Details >>
- No:23237
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is the maximum applicable load capacity at rated operational voltage. More Details >>
- No:23236
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
Release element in neutral (4P breaker)
AE-SW 4-poles with WS relay (general protection) has overcurrent protection for neutral-pole. The tripping characteristic is same as phase-pole. Moreover, A... More Details >>
- No:22441
- Release Date:2018/08/31 14:33
- Category: Air Circuit Breakers
-
This contact(SBC) is used to auxiliary switch(AXb) contact. When Drawout type ACB is moved from "test" position to "disconnect" position, AXb contact will b... More Details >>
- No:22416
- Release Date:2018/08/31 14:33
- Category: Air Circuit Breakers
-
Where UVT power supplied from?
Do not take the control power supply of UVT ("Resettable type" and "Reset prevention type") from the secondary side of the breakers. If taking the control po... More Details >>
- No:22415
- Release Date:2018/08/31 14:33
- Category: Accessories and Related Components
271-280 of Total 322