FAQ within [ Low-voltage Power Distribution Products ]
-
How to connect to 2-pole breaker
(1) When "N" is marked on the breaker,connect the N phase wire as marked. (2) When "N" is not marked on the breaker, N phase wire can be connected to eith... More Details >>
- No:37700
- Release Date:2020/01/17 08:58
- Category: Molded Case Circuit Breakers
-
About Low-voltage Power Distribution Products
The minimum applicable load is as follows. Contact reliability is indicatedby fault rate λ60 (Number of fault / Operating cycles per one contact) atthe relia... More Details >>
- No:23320
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
Cold start operating characteristic is the operating time from flowingcurrents to operating while a heater temparature of a thermal load relay isthe same as ... More Details >>
- No:23243
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
Almost ELCBs can be connected n reverse. Check the item column of specification table "reverse connection (below 230 V AC)" in the catalog. If it says "Possi... More Details >>
- No:22434
- Release Date:2018/08/31 14:33
- Category: Earth Leakage Circuit Breakers
-
Storage temperature range of MCCBs and ELCBs
It is from -25 to 55℃ in Trip or OFF position. However, it shall be in an environment without condensation and freezing even in a short time. More Details >>
- No:22426
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
-
Large electromagnetic force will be generated between conductors/wires due to fault currents. To prevent deformation and breakage of circuit breakers and con... More Details >>
- No:22424
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
-
All our products are compliant with CCC (China Compulsory Certification). More Details >>
- No:22386
- Release Date:2018/08/31 14:33
- Category: Circuit Breakers for Use in Particular Applications
-
Time Delay type at the maximum operating time
The maximum operating time of Time-delay type Earth Leakage Circuit Breaker can be switched to 0.45s, 1.0s and 2.0s. The operating time is:* when it is 0.45s... More Details >>
- No:22375
- Release Date:2018/08/31 14:33
- Category: Earth Leakage Circuit Breakers
-
The circuit breaker is designed to attain a predetermined value of limiting non-actuating time corresponding to a given value of residual current. Our time-d... More Details >>
- No:22351
- Release Date:2018/08/31 14:33
- Category: Earth Leakage Circuit Breakers
-
About Low-voltage Power Distribution Products
Main circuit of US-H* type is used for only AC power supply. For DC powersupply, we provide US-KD8 type solid state contactor. More Details >>