FAQ


FAQAbout Products
FAQ
Keyword Search
Low-voltage Power Distribution Products
FAQ within [ Low-voltage Power Distribution Products ]
-
Switch disconnector is a switch compatible with IEC 60947-3 standard, and it has no overcurrent tripping element. Please use it as a switch with large switch... More Details >>
- No:22379
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
-
About Low-voltage Power Distribution Products
It is a current value that can be closed (turning contact "ON") under theconditions specified in the standards. (In IEC, number of tests is 50times) More Details >>
- No:23294
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
For our reduced-voltage starter, when the starting time is over 15 sec,you need to review the selection of MCS and the wiring between MCD-MCS, and check whet... More Details >>
- No:23267
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
Surge voltage occurs due to opening/closing a control coil. Since we donot provide the surge suppressor for a control coil which is available forthem, you ne... More Details >>
- No:23285
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
When installing a thermal load relay in the delta phase and detectingphase current, you select a heater designation that can be set to 1 / √ 3times of the mo... More Details >>
- No:23240
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
Since the control coil of DU-N type is AC operation DC excitation methodof an electromagnet type and it includes the surge suppresing function.Therefore, a s... More Details >>
- No:23353
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
Short circuit current calculation software
You can calculate that with MELSHORT 2 (Free of charge). More Details >>
- No:22394
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
-
About Low-voltage Power Distribution Products
US-H* is designed for a heater load ,and a driving-circuit and selection ofa main circuit element are also designed to apply for a heater load andwhen applie... More Details >>
- No:23361
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
How to install cassette type accessories
A circuit breaker shall be Trip position when installing Cassette type accessory. The breaker may be damaged if installing in "ON" or "OFF" position. Moreove... More Details >>
- No:22422
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
-
degrees of protection to IEC60529
The degess of protection for ACB is IP20 as standard (under the condition that front door is closed). For MCCB and ELCB, the degrees of protection can be IP2... More Details >>
- No:24812
- Release Date:2019/04/09 15:18
- Category: Molded Case Circuit Breakers
291-300 of Total 322