FAQ


FAQAbout Products

FAQ
Keyword Search
Low-voltage Power Distribution Products
FAQ within [ Low-voltage Power Distribution Products ]
-
About Low-voltage Power Distribution Products
It is necessary to change the wires connected by solder to the board of theDL circuit since the wire length is short. Therefore, it is not possible toconnect... More Details >>
- No:23299
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
At ambient temperature 40℃, the rated voltage (frequency) is applied to acontrol coil, and after temperature rise and saturation, it can operatewithout any t... More Details >>
- No:23298
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is possible to apply for single-phase circuit. However, it may be lesseffect in single-phase circuit (100 V, etc) since low voltage circuit is tendedto be... More Details >>
- No:23297
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is a combination of a magnetic contactor and a thermal overload relay. More Details >>
- No:23296
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
In the case of DC, since the load current breaking is more difficultcompared to AC, permanent magnet is provided at each main contactpoint and the arc is dri... More Details >>
- No:23289
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
Since the leakage currents exist in a solid state contactor such as US-N/K/H type even when it is "OFF" state, it can not be used for insulatingload equipmen... More Details >>
- No:23288
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is a magnetic contactor that can reverse a motor by using two magneticcontactors and switching the connection of their contacts. More Details >>
- No:23287
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
Reverse connection is possible (connection of load side terminal as powerside and power side terminal as load side). However, it is necessary toinstall a mag... More Details >>
- No:23286
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
Surge voltage occurs due to opening/closing a control coil. Since we donot provide the surge suppressor for a control coil which is available forthem, you ne... More Details >>
- No:23285
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
At ambient temperature 40℃, the rated voltage (frequency) is applied to acontrol coil, and after temperature rise and saturation, it can operatewithout any t... More Details >>
- No:23278
- Release Date:2018/09/12 15:11
- Category: Motor Starters
301-310 of Total 322