FAQ
FAQAbout Products
FAQ
Keyword Search
Low-voltage Power Distribution Products
FAQ within [ Low-voltage Power Distribution Products ]
-
How to install cassette type accessories
A circuit breaker shall be Trip position when installing Cassette type accessory. The breaker may be damaged if installing in "ON" or "OFF" position. Moreove... More Details >>
- No:22422
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
-
Storage temperature range of MCCBs and ELCBs
It is from -25 to 55℃ in Trip or OFF position. However, it shall be in an environment without condensation and freezing even in a short time. More Details >>
- No:22426
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
-
ACB How to check the operating characteristic
Y-2005 type field test equipment (it is sold separately) enable to check the operating characteristic easily. The test is conducted by connecting the test te... More Details >>
- No:22429
- Release Date:2018/08/31 14:33
- Category: Air Circuit Breakers
-
There are Fixed type and Drawout type. More Details >>
- No:22430
- Release Date:2018/08/31 14:33
- Category: Air Circuit Breakers
-
In order to prevent breakdowns and human injuries, it is necessary to select a control device having protection structure suitable for each purpose. The prot... More Details >>
- No:22443
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
-
Max. operational voltage for AC/DC Common
When it is connected as special connection, AC/DC compatible circuit breaker can be used with DC 250V or more (3-pole type is DC400V and 4-pole type is DC500... More Details >>
- No:22445
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
-
About Low-voltage Power Distribution Products
It is the maximum applicable load capacity at rated operational voltage. More Details >>
- No:23236
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is a starting method that motor winding is star-connected and startingcurrent is set as one-third of direct-on-line and then it is delta-connectedafter ac... More Details >>
- No:23237
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
In our 3-contactor type star-delta starter (EYD), in order to eliminate thebreaking duty of the star contactor (MCS), the main contactor (MCM)break the star-... More Details >>
- No:23239
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is utilization category specified in IEC 60947-4-1. AC-3 category is usedfor starting a motor or stopping during operation etc. More Details >>
- No:23241
- Release Date:2018/09/12 15:11
- Category: Motor Starters
41-50 of Total 323