Low-voltage Power Distribution Products
FAQ within [ Low-voltage Power Distribution Products ]
-
It is possible to use it if you connect with right and left poles, not neutral pole. Since electronic circuit power supply for earth leakage detection is tak... More Details >>
- No:22359
- Release Date:2018/08/31 14:33
- Category: Earth Leakage Circuit Breakers
-
Checking the set values (ME96SS series).
Pressing the buttons of the “Set” for 2 seconds or more shifts the mode to the “Setting Value Confirmation Mode”. It is impossible to change the set values... More Details >>
- No:22165
- Release Date:2018/08/27 16:41
- Category: Electrical Indicators
-
About Low-voltage Power Distribution Products
When carrying the rated current at ambient temperature of 40℃ (whencarrying the rated heater load), the maximum temparature of cooling finis approximately 100℃. More Details >>
- No:23358
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
The minimum applicable load is 20V, 3mA . Contact reliability is indicatedby fault rate λ60 (Number of fault / Operating cycles per one contact) atthe reliab... More Details >>
- No:23304
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It stops a motor rapidly by reversing connetion of a contact. More Details >>
- No:23262
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
Earth leakage protective coordination
Since the total electric circuit length of upstream circuit breaker side is longer than that of downstream circuit breaker, constant earth leakage current b... More Details >>
- No:22369
- Release Date:2018/08/31 14:33
- Category: Earth Leakage Circuit Breakers
-
Availability for battery exchange for Logging Unit (ME96SS series).
The battery of the Logging unit (ME-0000BU-SS96) is NOT exchangeable. Please order a new unit. More Details >>
- No:22152
- Release Date:2018/08/27 16:41
- Update:2020/04/10 15:54
- Category: Electrical Indicators
-
Standards for this model (ME96SS series).
This model is compliant with CE marking, UL standard, KC Mark and FCC/IC. More Details >>
- No:22146
- Release Date:2018/08/27 16:41
- Update:2020/04/10 14:27
- Category: Electrical Indicators
-
About Low-voltage Power Distribution Products
The maximum ambient temparature for US-N/K/H type is 60℃ and theycan not be used with more than 60℃. If the temparature is more than60℃, you need to consider... More Details >>
- No:23346
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
CP30-BA AL and AX switch micro-load can be provided. And the number of installation is same as standard AL and AX switch. However, if multiple AL and AX are ... More Details >>
- No:22427
- Release Date:2018/08/31 14:33
- Category: Circuit Breakers for Equipment
41-50 of Total 322