About Low-voltage Power Distribution Products
For US-N5/8SS(TE) and US-N70/80NS(TE), the rated impulse withstandvoltage is 4kV. For US-N20 to 50(TE) and US-NH70/NH80NS(TE), the ratedimpulse withstand vol... More Details >>
- No:23322
- Release Date:2018/09/12 15:11
- Update:2018/09/26 09:22
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is possible to apply if the rated operating current value of a magneticcontator is more than the total rated current of motors. However, athermal load rel... More Details >>
- No:23263
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
Drawout type circuit breaker can be drawn-out and insert to the cradle without taking out the connecting conductor. As ACB is drawn out, it will be "connect ... More Details >>
- No:22431
- Release Date:2018/08/31 14:33
- Category: Air Circuit Breakers
-
Where UVT power supplied from?
Do not take the control power supply of UVT ("Resettable type" and "Reset prevention type") from the secondary side of the breakers. If taking the control po... More Details >>
- No:22415
- Release Date:2018/08/31 14:33
- Category: Accessories and Related Components
-
F-type and V-type operating handle
Both of F-type and V-type can remotely operate a circuit breaker in the panel board and the design of 800A fame or less are unified. Features are as follows.... More Details >>
- No:22389
- Release Date:2018/08/31 14:33
- Category: Accessories and Related Components
-
No, you must not use 2-pole circuit breaker as 1-pole circuit breaker (series connection as only single phase ). If using it as 1-pole circuit breaker, these... More Details >>
- No:22382
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
-
SHT has a burning prevention switch and it does not burn even if external switch remains "ON" state (After the circuit breaker trips, a burning prevention sw... More Details >>
- No:22355
- Release Date:2018/08/31 14:33
- Category: Accessories and Related Components
-
ELCB applicable to harmonics and surge
Compared with general circuit breakers, Earth Leakage Circuit Breaker applicable to harmonics and surge has earth leakage current detecting characteristic wh... More Details >>
- No:22344
- Release Date:2018/08/31 14:33
- Category: Earth Leakage Circuit Breakers
-
Response speed of the analog output (ME96SS series).
The response speed of the analog output is 2 seconds or less. The response speed of harmonic measurement is 10 seconds or less. More Details >>
- No:22157
- Release Date:2018/08/27 16:41
- Update:2020/04/10 16:12
- Category: Electrical Indicators
-
About Low-voltage Power Distribution Products
The head-on type of UN-AX 2 and AX 4 type can be installed. The side-onunit of UN-AX 11 type can not be installed. More Details >>
- No:23342
- Release Date:2018/09/12 15:12
- Category: Motor Starters