Recommended update period (ME96SS series).
The expected lifetime is 10 years. Is recommended to replace the device every 10 year. However the environment of installed location, such as temperature ... More Details >>
- No:22154
- Release Date:2018/08/27 16:41
- Update:2020/04/10 16:02
- Category: Electrical Indicators
-
Branch connection for MODBUS RTU communication
No, it is impossible. But Multi-drop connection is possible. For details, refer to connection examples as below. More Details >>
- No:24808
- Release Date:2019/03/27 14:44
- Category: Electrical Indicators , Energy Measuring Units
-
About Low-voltage Power Distribution Products
At ambient temperature 40℃, the rated voltage (frequency) is applied to acontrol coil, and after temperature rise and saturation, it can operatewithout any t... More Details >>
- No:23298
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is possible to apply if the rated operating current value of a magneticcontator is more than the total rated current of motors. However, athermal load rel... More Details >>
- No:23263
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
Inst tripping current value of AC/DC common breaker
At time-delay tripping zone, it operates with bimetal, therefore the characteristics of AC and DC should be same if the effective values of them are same. Ho... More Details >>
- No:22392
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
-
Inverse time delay operating characteristic
It is a characteristic that operating time inversely become shorter as current increases. For Molded Case Circuit Breakers, protection characteristic meeting... More Details >>
- No:22387
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
-
About Low-voltage Power Distribution Products
The minimum applicable load is as follows. Contact reliability is indicatedby fault rate λ60 (Number of fault / Operating cycles per one contact) atthe relia... More Details >>
- No:23320
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
This contact(SBC) is used to auxiliary switch(AXb) contact. When Drawout type ACB is moved from "test" position to "disconnect" position, AXb contact will b... More Details >>
- No:22416
- Release Date:2018/08/31 14:33
- Category: Air Circuit Breakers
-
When the AC waveform distorted due to harmonics, the value changes. (For AC without harmonics, the calculated value will match with the displayed value.) A... More Details >>
- No:22178
- Release Date:2018/08/27 16:41
- Update:2020/04/10 16:56
- Category: Electrical Indicators
-
Support status for IEC61850 (ME96SS series).
This model does NOT comply with the IEC61850. More Details >>
- No:22147
- Release Date:2018/08/27 16:41
- Update:2020/04/10 15:11
- Category: Electrical Indicators