Measuring harmonics range (ME96SS series).
ME96SSHB-MB • Total harmonics and odd orders of harmonics from 1st to 31st •Effective value and distortion rate. • Harmonic current and Harmonic... More Details >>
- No:22173
- Release Date:2018/08/27 16:41
- Update:2020/04/10 16:46
- Category: Electrical Indicators
-
Operation at the reversed phase connection (ME96SS series).
This model operates normally even at the reversed phase sequence. It is unnecessary to change wiring. More Details >>
- No:22170
- Release Date:2018/08/27 16:41
- Update:2020/04/10 16:41
- Category: Electrical Indicators
-
Availability of an option for ME96NS Series (ME96SS series).
An option for ME96NS series can NOT be installed to the main body of ME96SS series. An option for ME96SS series can NOT be installed to the main body of ME9... More Details >>
- No:22162
- Release Date:2018/08/27 16:41
- Category: Electrical Indicators
-
Wire length for analog output and contact output(ME96SS series)
It depends on the service conditions. Refer to the following guidelines. ① Contact output Contact output for ME96 series is no-voltage "a" contact. The... More Details >>
- No:24807
- Release Date:2019/03/27 12:12
- Category: Electrical Indicators
-
Availability for changing set values while operating (ME96SS series).
It is no problem. The memorized data such as active energy, reactive energy, and apparent energy is not deleted. The measurement is continued during setti... More Details >>
- No:22164
- Release Date:2018/08/27 16:41
- Update:2020/04/10 16:19
- Category: Electrical Indicators
-
Measurable minimum voltage (ME96SS series).
In case of the input voltage of less than 11 V, the measurement values are as follows: Voltage: 0 V,Power supply: 0 W, Reactive power: 0 var, Apparent pow... More Details >>
- No:22156
- Release Date:2018/08/27 16:41
- Update:2020/04/10 16:08
- Category: Electrical Indicators
-
Display digit of ACTIVE ENERGY
In the case of "6-digit display", the upper 3 digits of "9-digit display" are hidden. For details, refer to the Instrument User's Manual which you use. ・El... More Details >>
- No:24809
- Release Date:2019/03/27 14:44
- Category: Electrical Indicators
-
Setting for communication (ME96SS series).
1) For the main body of ME96: Please set the following values on the “Set-up menu 2”. In case of MODBUS RTU Set-up menu No. Setti... More Details >>
- No:22181
- Release Date:2018/08/27 16:41
- Update:2020/04/10 17:05
- Category: Electrical Indicators
-
Availability of an option for ME96NS Series (ME96SS series).
An option for ME96NS series can NOT be installed to the main body of ME96SS series. An option for ME96SS series can NOT be installed to the main body of ME... More Details >>
- No:22167
- Release Date:2018/08/27 16:41
- Category: Electrical Indicators
-
Initialization the set values (ME96SS series).
It is possible to initialize set values depending on setting. The method of initializing the setting value differs depending on the model. More Details >>
- No:22166
- Release Date:2018/08/27 16:41
- Update:2020/04/10 16:21
- Category: Electrical Indicators