Power Management Meters
FAQ within [ Power Management Meters ]
-
Standards for this model (ME96SS series).
This model is compliant with CE marking, UL standard, KC Mark and FCC/IC. More Details >>
- No:22146
- Release Date:2018/08/27 16:41
- Update:2020/04/10 14:27
- Category: Electrical Indicators
-
Concurrent-use of MODBUS RTU and CC-Link.
MODBUS RTU communication and CC-Link communication can be used at the same time. More Details >>
- No:22187
- Release Date:2018/08/27 16:41
- Category: Electrical Indicators
-
Recommended update period (ME96SS series).
The expected lifetime is 10 years. Is recommended to replace the device every 10 year. However the environment of installed location, such as temperature ... More Details >>
- No:22154
- Release Date:2018/08/27 16:41
- Update:2020/04/10 16:02
- Category: Electrical Indicators
-
As to exchange the LCD (ME96SS series).
The LCD cannot be exchanged. More Details >>
- No:22145
- Release Date:2018/08/27 16:41
- Update:2020/04/10 14:05
- Category: Electrical Indicators
-
Please check the register addresses. The register address for the present value of the power factor of each phase is “0789”. There are the register addre... More Details >>
- No:22191
- Release Date:2018/08/27 16:41
- Category: Electrical Indicators
-
Error in the measurement value (ME96SS series).
There is a possibility of the wiring error for VT/CT to this model. Please check the wiring for VT/CT and this model. More Details >>
- No:22179
- Release Date:2018/08/27 16:41
- Category: Electrical Indicators
-
Response speed of the analog output (ME96SS series).
The response speed of the analog output is 2 seconds or less. The response speed of harmonic measurement is 10 seconds or less. More Details >>
- No:22157
- Release Date:2018/08/27 16:41
- Update:2020/04/10 16:12
- Category: Electrical Indicators
-
Accuracy class index of active energy
Accuracy class index of active energy is a number which gives the limits of the permissible percentage error as defined in the IEC62053-22. More Details >>
- No:37704
- Release Date:2020/01/29 18:36
- Category: Electrical Indicators
-
Compensation for power failure (ME96SS series).
The setting data are memorized in nonvolatile memory, so the data is not deleted at the time of a power interruption. (The main body does not use a battery.)... More Details >>
- No:22163
- Release Date:2018/08/27 16:41
- Update:2020/04/10 16:16
- Category: Electrical Indicators
-
Power supply upon setting (ME96SS series).
It is necessary to supply an auxiliary power. As for an auxiliary power supply, you can use 50 Hz or 60 Hz from 100 VAC to 240 VAC and from 100 VDC to 240... More Details >>
- No:22161
- Release Date:2018/08/27 16:41
- Update:2020/04/10 16:14
- Category: Electrical Indicators