Wiring for only measuring current (ME96SS series).
It is unnecessary. (It is necessary to prepare an auxiliary power supply which supplies power between MA and MB.) More Details >>
- No:22174
- Release Date:2018/08/27 16:41
- Update:2020/04/10 16:50
-
Measurable minimum voltage (ME96SS series).
In case of the input voltage of less than 11 V, the measurement values are as follows: Voltage: 0 V,Power supply: 0 W, Reactive power: 0 var, Apparent pow... More Details >>
- No:22156
- Release Date:2018/08/27 16:41
- Update:2020/04/10 16:08
-
Measuring harmonics range (ME96SS series).
ME96SSHB-MB • Total harmonics and odd orders of harmonics from 1st to 31st •Effective value and distortion rate. • Harmonic current and Harmonic... More Details >>
- No:22173
- Release Date:2018/08/27 16:41
- Update:2020/04/10 16:46
-
Availability for changing set values while operating (ME96SS series).
It is no problem. The memorized data such as active energy, reactive energy, and apparent energy is not deleted. The measurement is continued during setti... More Details >>
- No:22164
- Release Date:2018/08/27 16:41
- Update:2020/04/10 16:19
-
The power factor does not match the indication values through MODBUS.
Please check the register addresses. The register address for the present value of the power factor of each phase is “0789”. There are the register... More Details >>
- No:37807
- Release Date:2020/04/10 15:10
-
Register address for active energy monitors in the MODBUS RTU communication (ME96SS series).
The acquired digit length of “1280”, “1281” and “1304” varies with the full load power. The acquired digit length of “1304” is 6-digit. Each of “1280” and... More Details >>
- No:22184
- Release Date:2018/08/27 16:41
- Update:2020/04/10 17:18
-
Checking the set values (ME96SS series).
Pressing the buttons of the “Set” for 2 seconds or more shifts the mode to the “Setting Value Confirmation Mode”. It is impossible to change the set values... More Details >>
- No:22165
- Release Date:2018/08/27 16:41
-
Communication failure with the upper system through MODBUS RTU.
Please check the following items. (A) Is the power supplied between MA and MB? (When the power is not supplied, the display does not work.) (B) Is the wir... More Details >>
- No:22182
- Release Date:2018/08/27 16:41
- Update:2020/04/10 17:08
-
Read data stored by the built-in logging function
The stored data can be read from MODBUS RTU communication. To use this function, MODBUS RTU communication is required. It is not available with MOD... More Details >>
- No:37808
- Release Date:2020/04/10 15:09
-
Acquired values through MODBUS RTU.
The acquired value by communication should be multiplied by the multiplying factor to change into the measurement value. Please refer to Section 7.3 of ... More Details >>
- No:22183
- Release Date:2018/08/27 16:41
- Update:2020/04/13 09:13