Network number (Net No.) and station number in the controller settings
The following shows the network number (Net No.) and the station number to be set in the controller settings. • The network number (Net No.) is assigned to ... More Details >>
- No:45257
- Release Date:2025/10/22 17:08
-
Switching the GOT screen from being displayed to hidden
Switching is enabled by using the system information (read device). The GOT screen can be displayed/hidden by turning ON/OFF the Forced Screen Saver Enable ... More Details >>
- No:45295
- Release Date:2025/10/22 17:12
-
How to control the screen saver from the PLC
The screen save can be controlled from the PLC. Use the system information (read device). When the Forced Screen Saver Enable signal (System signal 1-1.b1)... More Details >>
- No:45248
- Release Date:2025/10/22 17:06
-
If the window screen does not display, confirm the following. • The screen switching device for the window screen to be used is set in the screen design sof... More Details >>
- No:45238
- Release Date:2025/10/22 16:51
-
Unable to input by touching the key window
If input by touching the key window is not possible, check the display settings of the cursor. Even if the key window is displayed, input is not possible if... More Details >>
- No:45271
- Release Date:2025/10/22 17:10
-
Ethernet connection between the GOT and multiple QnUDVCPUs
The following shows an example of settings to connect a single GOT to the built-in Ethernet ports of multiple QnUDVCPUs via Ethernet. 1. Configure the follo... More Details >>
- No:23444
- Release Date:2018/09/14 15:06
- Update:2025/10/16 16:05
-
PLC access from GX Works3 via the GOT
When connecting the personal computer (GX Works3) and the built-in Ethernet interface of the RnCPU via the USB interface of the GOT3000 series or GOT2000 ser... More Details >>
- No:23490
- Release Date:2018/09/14 15:06
- Update:2025/10/09 17:33
-
How to display integer values written to the PLC as real numbers (with decimal points) on the GOT
Use the automatic decimal place adjustment function to display the integer value written to the PLC as a real number on the numerical display on the GOT. Co... More Details >>
- No:45291
- Release Date:2025/10/22 17:12
-
Sample project (sample design data) for GOT2000
Sample projects (sample design data) for the GOT2000 series are supplied with GT Works3 (GOT2000) Version 1.100E or later. The sample projects are stored in ... More Details >>
- No:23511
- Release Date:2018/09/14 15:06
-
How to control GOT buzzer from the PLC
The GOT buzzer can be controlled from the PLC. Use the system information (read device). • Buzzer Three-shot Output signal (System signal 1-1.b8) • Buzzer... More Details >>
- No:45247
- Release Date:2025/10/23 10:54