Converting a logging file (binary format) to a CSV file
The following methods can be used to convert binary format logging files (*.G3L, *.G2L, or *.G1L) to CSV format. 1. Conversion using the GOT utility functio... More Details >>
- No:45277
- Release Date:2025/10/22 17:11
-
PLC access from GX Works3 via the GOT
When connecting the personal computer (GX Works3) and the built-in Ethernet interface of the RnCPU via the USB interface of the GOT3000 series or GOT2000 ser... More Details >>
- No:23490
- Release Date:2018/09/14 15:06
- Update:2025/10/09 17:33
-
Transferring the resource data from the GOT to a personal computer
You can transfer the resource data of the GOT2000 series to a personal computer without using the screen design software in any of the following methods. 1. ... More Details >>
- No:23513
- Release Date:2018/09/14 15:06
-
The following shows how to check that the USB driver for GT Designer3 is installed on the personal computer. 1. Connect the personal computer and GOT using ... More Details >>
- No:45270
- Release Date:2025/10/22 17:10
-
Ethernet connection with the QnUD(H)CPU
The following describes an example of settings to connect a GT27, GT25, or GT21 model (Ethernet connection model) and the QnUD(H)CPU by Ethernet by using QJ7... More Details >>
- No:23441
- Release Date:2018/09/14 15:06
- Update:2018/09/26 16:57
-
Timing of when changes to the PLC CPU's clock data are reflected to the GOT
If changing the clock data of the PLC CPU does not change the clock data of the GOT, check that time adjustment is set on the GOT or in GT Designer3. • GT37... More Details >>
- No:45286
- Release Date:2025/10/22 17:12
-
How to display integer values written to the PLC as real numbers (with decimal points) on the GOT
Use the automatic decimal place adjustment function to display the integer value written to the PLC as a real number on the numerical display on the GOT. Co... More Details >>
- No:45291
- Release Date:2025/10/22 17:12
-
How to control GOT buzzer from the PLC
The GOT buzzer can be controlled from the PLC. Use the system information (read device). • Buzzer Three-shot Output signal (System signal 1-1.b8) • Buzzer... More Details >>
- No:45247
- Release Date:2025/10/23 10:54
-
Ethernet connection between multiple GOTs and the QnUDVCPU
The following shows an example of settings to connect multiple GOTs to the built-in Ethernet port of the QnUDVCPU via Ethernet. 1. Configure the following s... More Details >>
- No:23443
- Release Date:2018/09/14 15:06
- Update:2025/10/16 14:21
-
Checking the screen number of the displayed screen on the GOT
The screen number displayed on the GOT can be monitored with the PLC. Perform one of the following operations. 1. Monitor the screen switching device. Set ... More Details >>
- No:45275
- Release Date:2025/10/22 17:11