FAQ


FAQAbout Products
FAQ
Keyword Search
FAQ within [ GT25 ]
-
Device data transfer between devices connected to the GOT
The GOT2000 series allows device data to be transferred among multiple controllers (among PLCs, PLCs and temperature controllers, etc.). For the details o... More Details >>
- No:23499
- Release Date:2018/09/14 15:06
- Update:2018/09/25 17:29
-
Differences in the panel cutting dimensions from the GOT1000 series
The GOT1000 series and GOT2000 series have the same panel cutting dimensions when their models are the same in screen sizes (excluding the GT25 open frame mo... More Details >>
- No:23421
- Release Date:2018/09/14 15:06
- Update:2018/09/26 16:37
-
Lifespans of SD and CF memory cards (number of write cycles)
For information on the lifespans of SD and CF memory cards (number of write cycles), check the specifications of the memory card to be used. The lifespans o... More Details >>
- No:45297
- Release Date:2025/10/22 17:12
-
Transferring the resource data from the GOT to a personal computer
You can transfer the resource data of the GOT2000 series to a personal computer without using the screen design software in any of the following methods. 1. ... More Details >>
- No:23513
- Release Date:2018/09/14 15:06
-
Use of commercially available SD memory cards for the GOT2000 series
You can use commercially available SD memory cards for the GOT2000 series. Note that we do not guarantee the operation when commercially available USB memori... More Details >>
- No:23494
- Release Date:2018/09/14 15:06
-
Common license of the VNC server function
The license of the VNC server function for the GOT1000 series cannot be used for the GOT2000 series. Use the license for the GOT2000 series (GT25-VNCSKEY). More Details >>
- No:23426
- Release Date:2018/09/14 15:06
- Update:2020/01/07 15:48
-
The IP address of the GOT is used for another device (including GOT) as well. Please change the IP address of the GOT to another one by one of the following ... More Details >>
- No:23449
- Release Date:2018/09/14 15:06
- Update:2018/09/26 17:10
-
You can try the VNC server function up to 30 times in total (up to 15 hours) by counting one continuous use within 30 minutes as one time. More Details >>
- No:23427
- Release Date:2018/09/14 15:06
- Update:2020/01/07 15:49
-
How to check the battery voltage
The battery voltage can be checked using either of the following methods. 1. Check using the GOT utility function • For the GT37, GT27, and GT25 Select [... More Details >>
- No:45280
- Release Date:2025/10/22 17:11
-
How to set the network number and station number for connection to RCPU and QnUD(P)VCPU
To connect the RCPU or QnUD(P)VCPU to the GOT by setting the network number and station number using project data transfer via the PLC or other methods, conf... More Details >>
- No:45268
- Release Date:2025/10/22 17:10