Device data transfer between devices connected to the GOT
The GOT2000 series allows device data to be transferred among multiple controllers (among PLCs, PLCs and temperature controllers, etc.). For the details o... More Details >>
- No:23499
- Release Date:2018/09/14 15:06
- Update:2018/09/25 17:29
-
Support for the GOT3000 series and GOT2000 series by the Data Transfer Tool
You can use Data Transfer Tool to transfer the project data of the GOT3000 series and GOT2000 series. If your Data transfer tool does not support your GOT... More Details >>
- No:23498
- Release Date:2018/09/14 15:06
- Update:2025/10/09 18:38
-
Timing of when changes to the PLC CPU's clock data are reflected to the GOT
If changing the clock data of the PLC CPU does not change the clock data of the GOT, check that time adjustment is set on the GOT or in GT Designer3. • GT37... More Details >>
- No:45286
- Release Date:2025/10/22 17:12
-
Support of GT Designer3 by the GOT2000 series
You can create a project data for the GOT2000 series using GT Designer3 (GOT2000) Version 1.100E or later. If you use Version 1.100E or earlier of GT Designe... More Details >>
- No:23512
- Release Date:2018/09/14 15:06
-
Connecting the GOT2000 series and a barcode reader or other devices by USB
You can connect a GOT2000 series model with a barcode reader or 2D code reader by USB. RFID does not support USB connection. Note that a barcode reader o... More Details >>
- No:23495
- Release Date:2018/09/14 15:06
- Update:2018/09/25 17:30
-
Ethernet connection with QnUDVCPU
The following describes an example of settings to connect a GT27, GT25, or GT21 model (Ethernet connection model) and the QnUDVCPU by Ethernet by using the b... More Details >>
- No:23442
- Release Date:2018/09/14 15:06
- Update:2018/09/26 16:58
-
How to display integer values written to the PLC as real numbers (with decimal points) on the GOT
Use the automatic decimal place adjustment function to display the integer value written to the PLC as a real number on the numerical display on the GOT. Co... More Details >>
- No:45291
- Release Date:2025/10/22 17:12
-
Transferring the resource data from the GOT to a personal computer
You can transfer the resource data of the GOT2000 series to a personal computer without using the screen design software in any of the following methods. 1. ... More Details >>
- No:23513
- Release Date:2018/09/14 15:06
-
Using RS-232 connection and Ethernet connection together
The GT27, GT25, or GT21 model (Ethernet connection models) can monitor up to four controllers (four channels) (such as PLC CPU, temperature controller, and i... More Details >>
- No:23445
- Release Date:2018/09/14 15:06
- Update:2018/09/26 17:02
-
IP address settings when connecting the GOT to a PLC via Ethernet
When connecting the GOT to a PLC via Ethernet, set the IP address of the PLC in the screen design software. ◆ For GT Designer3 (GOT2000) Version 1 Select [... More Details >>
- No:45282
- Release Date:2025/10/22 17:11