Using with the GOT1000 series in a GOT multi-drop topology
The GOT1000 series and GOT2000 series can be used together in the GOT multi-drop topology. Use GT Designer3 (GOT1000) Version 1.12N or later to write the bas... More Details >>
- No:23496
- Release Date:2018/09/14 15:06
-
Compatibility of communication cables for the GOT1000 series
Only when the connectors have the same number of pins, shape, and communication format, the communication cable for the GOT1000 series can be used for the GO... More Details >>
- No:23422
- Release Date:2018/09/14 15:06
- Update:2018/09/26 16:38
-
When connecting the MELSEC iQ-F series (FX5U, FX5UC, FX5UJ, or FX5S) via Ethernet, set Port No. in Connected Ethernet Controller Setting as shown in Table 2.... More Details >>
- No:45266
- Release Date:2025/10/22 17:10
-
Open settings for connection to the built-in Ethernet port of the MELSEC iQ-R series
Open settings are required when the communication method of the GOTs is TCP for a single MELSEC iQ-R series controller (built-in Ethernet port). Configure t... More Details >>
- No:45267
- Release Date:2025/10/22 17:10
-
You can place an object anywhere you like in the screen design software instead of aligning it with the grid lines. ◆ For GT Designer3 (GOT2000) Version 1 ... More Details >>
- No:45249
- Release Date:2025/10/22 17:07
-
Use of a commercially available USB cable for the GOT2000 series
While you can use commercially available USB cables for the GOT2000 series, we have guaranteed the operation only when one of the following cables is used. ... More Details >>
- No:23491
- Release Date:2018/09/14 15:06
- Update:2018/09/25 17:36
-
How to increase the display speed of the GOT
The following methods may increase the display speed. 1. Reduce the number of objects. 2. Configure the trigger actions and script settings per screen, not... More Details >>
- No:45287
- Release Date:2025/10/22 17:11
-
Storing the PLC device value in the GOT internal device when starting the GOT
The PLC device value can be stored in the GOT internal device when the GOT is started by using GB40 (always on) as a trigger. Since GB40 is on when the GOT ... More Details >>
- No:45298
- Release Date:2025/10/22 17:13
-
If the GOT screen is black and does not respond to touch, check the POWER LED on the main unit. • Solid orange Cause: Screen saver is active Solution: Che... More Details >>
- No:45301
- Release Date:2025/10/23 10:53
-
Checking the screen number of the displayed screen on the GOT
The screen number displayed on the GOT can be monitored with the PLC. Perform one of the following operations. 1. Monitor the screen switching device. Set ... More Details >>
- No:45275
- Release Date:2025/10/22 17:11