FAQ within [ GT37 ]
-
Storing the PLC device value in the GOT internal device when starting the GOT
The PLC device value can be stored in the GOT internal device when the GOT is started by using GB40 (always on) as a trigger. Since GB40 is on when the GOT ... More Details >>
- No:45298
- Release Date:2025/10/22 17:13
-
Historical trend graph function
The historical graph function displays the device data (logging data) collected using the logging function chronologically in a graph. This function, unlike... More Details >>
- No:45242
- Release Date:2025/10/22 17:03
-
Specifying the display position of the key window
Specify the display position of the key window in the screen design software as follows. ◆ GT Designer3 (GOT3000) Version 1, GT Designer3 (GOT2000) Version ... More Details >>
- No:45299
- Release Date:2025/10/22 17:13
-
Setting the PLC station number when connecting the GOT to the PLC via Ethernet
The following shows how to set the PLC station number when connecting the GOT to the PLC via Ethernet. Configure the settings in the screen design software.... More Details >>
- No:45293
- Release Date:2025/10/22 17:12
-
Switching the GOT screen from being displayed to hidden
Switching is enabled by using the system information (read device). The GOT screen can be displayed/hidden by turning ON/OFF the Forced Screen Saver Enable ... More Details >>
- No:45295
- Release Date:2025/10/22 17:12
-
How to set the network number and station number for connection to RCPU and QnUD(P)VCPU
To connect the RCPU or QnUD(P)VCPU to the GOT by setting the network number and station number using project data transfer via the PLC or other methods, conf... More Details >>
- No:45268
- Release Date:2025/10/22 17:10
-
The alarm popup display function can display the current alarm information in the foreground. Configure the settings in the screen design software. ◆ For G... More Details >>
- No:45292
- Release Date:2025/10/22 17:12
-
Ethernet connection between one PLC and two GOTs
Yes. Multiple GOTs (GOT 3000 series and GOT 2000 series) can be connected to one Mitsubishi Electric PLC via Ethernet. The number of connectable GOTs differs... More Details >>
- No:23446
- Release Date:2018/09/14 15:06
- Update:2025/10/09 17:34
-
Unable to input by touching the key window
If input by touching the key window is not possible, check the display settings of the cursor. Even if the key window is displayed, input is not possible if... More Details >>
- No:45271
- Release Date:2025/10/22 17:10
-
Reasons for slow screen switching
Possible causes of slow screen switching are as follows: • The incorrect communication driver is selected. • When connected via Ethernet, a device with a d... More Details >>
- No:45283
- Release Date:2025/10/22 17:11
61-70 of Total 85