FAQ
FAQAbout Products
FAQ
Keyword Search
Energy Saving Supporting Devices
FAQ within [ Energy Saving Supporting Devices ]
-
Extension of current sensor cable (EcoMonitorPlus/Light).
Use an extension cable (Model: EMU2-CB-T1M / EMU2-CB-T5M/EMU2-CB-T10M / EMU2-CB-T1MS / EMU2-CB-T5MS / EMU2-CB-T10MS) for extending the cable between EcoMonit... More Details >>
- No:22118
- Release Date:2018/08/27 16:41
- Update:2018/09/07 11:47
- Category: Energy Measuring Units
-
Checking the IP address of EcoWebServerIII
(1) Open the front cover on the server section, and set the MODE switch to the "STOP" position. (2) Set the RESET switch to the "SEL." position. (3) After ... More Details >>
- No:38044
- Release Date:2021/02/25 17:54
- Category: Energy Saving Data Collecting Servers
-
As to changing location of the decimal point and units of the measured value.
Since location of the decimal point or units of the measured value displayed is decided by Total load power, it is impossible to change location of the decim... More Details >>
- No:22139
- Release Date:2018/08/27 16:41
- Category: Energy Measuring Units
-
As to logging period of the internal memory of the main unit.
Logging period of the internal memory of the main unit as following: 1. In case of detailed data Logging period differs according to logging cycle for deta... More Details >>
- No:22137
- Release Date:2018/08/27 16:41
- Update:2018/09/07 12:43
- Category: Energy Measuring Units
-
As to logging after removing an SD memory card.
Since the EMU4-LM performs data logging, it is possible to log the data even in a state of removing the SD memory card. Provided that the period for data l... More Details >>
- No:22134
- Release Date:2018/08/27 16:41
- Category: Energy Measuring Units
-
As to timing for outputting data file into the SD memory card.
EMU4-LM outputs data file at following timing. 1. When inserting the SD memory card while operating. 2. When power is ON in a state of the SD memory ca... More Details >>
- No:22133
- Release Date:2018/08/27 16:41
- Category: Energy Measuring Units
-
Connection failure upon one-to-one connecting a PC with EcoWebServerIII.
Please confirm as below. * Correct IP address? * Correct subnet mask? * Correct proxy setting on PC? * Correct LAN cable (no disconnection)? * Correct... More Details >>
- No:22115
- Release Date:2018/08/27 16:41
- Category: Energy Saving Data Collecting Servers
-
Checking the disconnection or communications error status of the Energy measuring Unit
There is no way to detect a disconnection or communications error in the Energy measuring Unit. As an alternative idea, we have two solutions to monitor t... More Details >>
- No:38043
- Release Date:2021/02/25 17:54
- Category: Energy Saving Data Collecting Servers
-
Cause of "minus" indication for electric power value (EcoMonitorPlus/Light).
Following causes are assumed for the error. 1. Wrong orientation of the sensor? 2. 1-side and 3-side of the sensor are reversed? 3. Is connection betwe... More Details >>
- No:22143
- Release Date:2018/08/27 16:41
- Category: Energy Measuring Units
-
As to compensation for power failure (EcoMonitorPlus/Light).
Since the setting value, integrated value (electric energy (consumption, regeneration), reactive energy, periodic electric energy, pulse count and operating ... More Details >>
- No:22141
- Release Date:2018/08/27 16:41
- Category: Energy Measuring Units
21-30 of Total 47