FAQ


FAQAbout Products
- FAQ > Energy Saving Supporting Devices > Energy Saving Supporting Devices
FAQ
Keyword Search
Energy Saving Supporting Devices
FAQ within [ Energy Saving Supporting Devices ]
-
As to indication of the measurement value of the electric energy (EcoMonitorPlus/Light).
It measures from 0kWh(MWh) after going round. Integer 4 digits : 9999.98→9999.99→0000.00→0000.01kWh(MWh) Integer 5 digits : 99999.8→99999.9→00000.0→0000... More Details >>
- No:22131
- Release Date:2018/08/27 16:41
- Category: Energy Measuring Units
-
Connection failure upon one-to-one connecting a PC with EcoWebServerIII.
Please confirm as below. * Correct IP address? * Correct subnet mask? * Correct proxy setting on PC? * Correct LAN cable (no disconnection)? * Correct... More Details >>
- No:22115
- Release Date:2018/08/27 16:41
- Category: Energy Saving Data Collecting Servers
-
As to action upon memory shortage of the SD memory card.
It will stop outputting logging data from the Logging Unit. [SD C.] LED will be high-speed blinking (repeat of 0.25sec ON → 0.25sec OFF). Backup the data ... More Details >>
- No:22135
- Release Date:2018/08/27 16:41
- Category: Energy Measuring Units
-
Method for measuring a circuit over 600A (EcoMonitorPlus/Light).
Attach a current transformer (CT) whose secondary current is 5A to the measuring point, then connect a split-type 5A current sensor (Model: EMU-CT5-A, EMU2-C... More Details >>
- No:22119
- Release Date:2018/08/27 16:41
- Update:2018/09/07 11:38
- Category: Energy Measuring Units
-
For file transfer period and file transfer time (EcoWebServerIII).
Files are transferred once an hour. Transfer time can be set from 10min / 20min / 30min / 40min / 50min. More Details >>
- No:22117
- Release Date:2018/08/27 16:41
- Category: Energy Saving Data Collecting Servers
-
Cautions for replacing a battery (EcoWebServerIII).
Surely OFF the power of the EcoWebServerIII (MES3-255C-EN, MES3-255C-DM-EN) when replacing battery. Replacing a battery while power ON may cause electric sho... More Details >>
- No:22112
- Release Date:2018/08/27 16:41
- Category: Energy Saving Data Collecting Servers
-
Simultaneous data acquisition of MODBUS RTU communication and Optional Unit.
It is possible to simultaneously collect data by MODBUS RTU communication and Optional Unit connected. Provided that MODBUS RTU communication cannot collec... More Details >>
- No:22140
- Release Date:2018/08/27 16:41
- Category: Energy Measuring Units
-
As to Zero-Phase Current Transformer (ZCT) usable for the EcoMonitorPlus (Model: EMU4-LG1-MB).
Refer to the below table as to Zero-Phase Current Transformer usable for EcoMonitorPlus (Model: EMU4-LG1-MB). Note that the one made by another company is... More Details >>
- No:22129
- Release Date:2018/08/27 16:41
- Update:2018/08/31 14:17
- Category: Energy Measuring Units
-
MEASURE LED not blink (EcoMonitorPlus).
MEASURE LED lights while measuring electric power over 0.4% of the total load power. Check below points: 1. Is voltage wiring connected? 2. Are the trans... More Details >>
- No:22144
- Release Date:2018/08/27 16:41
- Category: Energy Measuring Units
-
Download of EcoWebServerIII graph data.
Currently displayed date graph is downloadable. Downloaded data is not changed only by changing the date. Change date, then press [Display] to update the g... More Details >>
- No:22116
- Release Date:2018/08/27 16:41
- Category: Energy Saving Data Collecting Servers
31-40 of Total 47