Parameter group is not displayed.
Some parameters are write-protected. (MR-J4/MR-J3: PA19)The parameter to be displayed is determined by the setting value of this parameter. Do as follows for... More Details >>
- No:23657
- Release Date:2018/09/14 15:10
- Category: MELSERVO-J3 , MELSERVO-J4
-
Using MR Configurator2, you can perform the positioning operation when there is no command from the controller. You can perform the operation specifying the ... More Details >>
- No:23640
- Release Date:2018/09/14 15:10
- Category: Servo Support Software , MELSERVO-J4 , MELSERVO-JE , MELSERVO-JN , MELSERVO-J3
-
MR-J4(W)-B mode selection application
From Start menu of Windows >, click [All Programs] > - [MELSOFT Application] > - [MR Configurator2] > and you can find “MR-J4(W)-B mode selectio... More Details >>
- No:23637
- Release Date:2018/09/14 15:10
- Category: Servo Support Software , MELSERVO-J4
-
The one-touch tuning does not require the response level setting also. Outlines of one-touch tuning and auto tuning are as follows: One-touch tuning: You can... More Details >>
- No:23629
- Release Date:2018/09/14 15:10
- Category: MELSERVO-J4 , MELSERVO-JE
-
MR Configurator2 has been improved in the following. ・The servo assistant function introduces the related functions for each operation step to enable the f... More Details >>
- No:23658
- Release Date:2018/09/14 15:10
- Category: Servo Support Software
-
By either of following methods: (MR-J4) 1. On MR Configurator2, select [Diagnosis] - [Alarm Display] - [Clear]. 2. Set alarm history clear of parameter to "... More Details >>
- No:23650
- Release Date:2018/09/14 15:10
- Category: MELSERVO-J4
-
Wrong connection of servo amplifier power supply
The system is probably malfunctioning and is in dangerous condition. Do not use it. For repair, contact your local sales office. More Details >>
- No:23623
- Release Date:2018/09/14 15:10
- Category: MELSERVO-J4 , MELSERVO-JE
-
“off” is shown in the display.
Operation mode for manufacturer setting is enabled. For MR-J4-B, MR-J4W2-B and MR-J4W3-B, turning "ON (up)" all the control axis setting switches (SW2) enabl... More Details >>
- No:23625
- Release Date:2018/09/14 15:10
- Category: MELSERVO-J4
-
You can solder the wiring to the connector without using the junction terminal block (option). More Details >>
- No:23654
- Release Date:2018/09/14 15:10
- Category: MELSERVO-J4
-
Encoder resolution during J3 compatibility mode
18 bits (262,144 pulses/rev.) The encoder resolution of HG series servo motor in J4 mode is 22 bits (4,194,304 pulses/rev). For details of J3 compatibility m... More Details >>
- No:23630
- Release Date:2018/09/14 15:10
- Category: MELSERVO-J4 , MELSERVO-JE