- FAQ > Drive Products > AC Servos-MELSERVO
FAQ
Keyword Search
FAQ within [ AC Servos-MELSERVO ]
-
The following version or later is supported for Windows 8. MR Configurator2, 1.20W or later More Details >>
- No:23633
- Release Date:2018/09/14 15:10
- Category: Servo Support Software
-
Thickness of coating and length of cable provided More Details >>
- No:23651
- Release Date:2018/09/14 15:10
- Category: MELSERVO-J4 , MELSERVO-JE
-
“off” is shown in the display.
Operation mode for manufacturer setting is enabled. For MR-J4-B, MR-J4W2-B and MR-J4W3-B, turning "ON (up)" all the control axis setting switches (SW2) enabl... More Details >>
- No:23625
- Release Date:2018/09/14 15:10
- Category: MELSERVO-J4
-
Differences between type A and type B
MR-J4-A receives the motor drive command by general pulse train and MR-J4-B does by the optical communication, SSCNET III/H of our motion network. For the de... More Details >>
- No:23648
- Release Date:2018/09/14 15:10
- Category: MELSERVO-J4
-
MR Configurator2 has been improved in the following. ・The servo assistant function introduces the related functions for each operation step to enable the f... More Details >>
- No:23658
- Release Date:2018/09/14 15:10
- Category: Servo Support Software
-
Encoder resolution during J3 compatibility mode
18 bits (262,144 pulses/rev.) The encoder resolution of HG series servo motor in J4 mode is 22 bits (4,194,304 pulses/rev). For details of J3 compatibility m... More Details >>
- No:23630
- Release Date:2018/09/14 15:10
- Category: MELSERVO-J4 , MELSERVO-JE
-
Depending on each cable. Refer to each SSCNET III/H compatible servo amplifier instruction manual. More Details >>
- No:23652
- Release Date:2018/09/14 15:10
- Category: MELSERVO-J4 , MELSERVO-JE
-
SSCNET III/H during the power supply shut-off
In case that only main circuit power supply is cut off, communication remains. In case that the control circuit power supply of servo amplifier is cut off, t... More Details >>
- No:23646
- Release Date:2018/09/14 15:10
- Category: MELSERVO-J4
-
The one-touch tuning does not require the response level setting also. Outlines of one-touch tuning and auto tuning are as follows: One-touch tuning: You can... More Details >>
- No:23629
- Release Date:2018/09/14 15:10
- Category: MELSERVO-J4 , MELSERVO-JE
-
By either of following methods: (MR-J4) 1. On MR Configurator2, select [Diagnosis] - [Alarm Display] - [Clear]. 2. Set alarm history clear of parameter to "... More Details >>
- No:23650
- Release Date:2018/09/14 15:10
- Category: MELSERVO-J4