FAQ


FAQAbout Products
- FAQ > Drive Products > AC Servos-MELSERVO > MELSERVO-J4
FAQ
Keyword Search
FAQ within [ MELSERVO-J4 ]
-
Changing multiplication of analog torque command
Yes, it is. For MR-J4-A/MR-J3-A, set by [Pr. PC13]. As the initial value (100.0%), the maximum torque is generated at ±8 V. To generate the maximum torque a... More Details >>
- No:23628
- Release Date:2018/09/14 15:10
-
Parameter group is not displayed.
Some parameters are write-protected. (MR-J4/MR-J3: PA19)The parameter to be displayed is determined by the setting value of this parameter. Do as follows for... More Details >>
- No:23657
- Release Date:2018/09/14 15:10
-
Total capacity of servo amplifier to be connected to power regeneration common converter
Select the total capacity of the servo amplifier to be connected. For selecting combination of FR-CV power regeneration common converter and servo amplifier ... More Details >>
- No:23627
- Release Date:2018/09/14 15:10
-
The module power consumption displays the power consumption of servo motor. Positive value indicates power running and negative value indicates regeneration. More Details >>
- No:23636
- Release Date:2018/09/14 15:10
-
Depending on each cable. Refer to each SSCNET III/H compatible servo amplifier instruction manual. More Details >>
- No:23652
- Release Date:2018/09/14 15:10
-
Specifying the axis in test operation of MR-J4W
When the MR-J4-B is selected on the model selection screen at creating a new project, the multi-axis check box will be enabled. Click the check box and selec... More Details >>
- No:23635
- Release Date:2018/09/14 15:10
-
Encoder resolution during J3 compatibility mode
18 bits (262,144 pulses/rev.) The encoder resolution of HG series servo motor in J4 mode is 22 bits (4,194,304 pulses/rev). For details of J3 compatibility m... More Details >>
- No:23630
- Release Date:2018/09/14 15:10
-
Thickness of coating and length of cable provided More Details >>
- No:23651
- Release Date:2018/09/14 15:10
-
You can solder the wiring to the connector without using the junction terminal block (option). More Details >>
- No:23654
- Release Date:2018/09/14 15:10
-
Relationship between rotary switch and axis number
When the rotary switch is “0”, the 1st axis and is “1”, the 2nd axis. When the rotary switch is “A”, the 11th axis and is “F”, the 16th axis. In combination ... More Details >>
- No:23644
- Release Date:2018/09/14 15:10