FAQ within [ MELSERVO-J4 ]

11-20 of Total 29

prev 2 / 3page next
  • Positioning operation

    Using MR Configurator2, you can perform the positioning operation when there is no command from the controller. You can perform the operation specifying the ... More Details >>

    • No:23640
    • Release Date:2018/09/14 15:10
  • Encoder resolution during J3 compatibility mode

    18 bits (262,144 pulses/rev.) The encoder resolution of HG series servo motor in J4 mode is 22 bits (4,194,304 pulses/rev). For details of J3 compatibility m... More Details >>

    • No:23630
    • Release Date:2018/09/14 15:10
  • Clearing the alarm history

    By either of following methods: (MR-J4) 1. On MR Configurator2, select [Diagnosis] - [Alarm Display] - [Clear]. 2. Set alarm history clear of parameter to "... More Details >>

    • No:23650
    • Release Date:2018/09/14 15:10
  • Output check

    Using MR Configurator2, you can switch the output signals on/off forcibly independently of the servo status. This function is used for output signal wiring c... More Details >>

    • No:23639
    • Release Date:2018/09/14 15:10
  • Specifying the axis in test operation of MR-J4W

    When the MR-J4-B is selected on the model selection screen at creating a new project, the multi-axis check box will be enabled. Click the check box and selec... More Details >>

    • No:23635
    • Release Date:2018/09/14 15:10
  • One-touch tuning

    The one-touch tuning does not require the response level setting also. Outlines of one-touch tuning and auto tuning are as follows: One-touch tuning: You can... More Details >>

    • No:23629
    • Release Date:2018/09/14 15:10
  • Changing multiplication of analog torque command

    Yes, it is. For MR-J4-A/MR-J3-A, set by [Pr. PC13]. As the initial value (100.0%), the maximum torque is generated at ±8 V. To generate the maximum torque a... More Details >>

    • No:23628
    • Release Date:2018/09/14 15:10
  • SSCNET III/H during the power supply shut-off

    In case that only main circuit power supply is cut off, communication remains. In case that the control circuit power supply of servo amplifier is cut off, t... More Details >>

    • No:23646
    • Release Date:2018/09/14 15:10
  • Wrong connection of servo amplifier power supply

    The system is probably malfunctioning and is in dangerous condition. Do not use it. For repair, contact your local sales office. More Details >>

    • No:23623
    • Release Date:2018/09/14 15:10
  • SSCNET III cable type

    Depending on each cable. Refer to each SSCNET III/H compatible servo amplifier instruction manual. More Details >>

    • No:23652
    • Release Date:2018/09/14 15:10