Thickness of coating and length of cable provided More Details >>
- No:23651
- Release Date:2018/09/14 15:10
-
By either of following methods: (MR-J4) 1. On MR Configurator2, select [Diagnosis] - [Alarm Display] - [Clear]. 2. Set alarm history clear of parameter to "... More Details >>
- No:23650
- Release Date:2018/09/14 15:10
-
SSCNET III/H during the power supply shut-off
In case that only main circuit power supply is cut off, communication remains. In case that the control circuit power supply of servo amplifier is cut off, t... More Details >>
- No:23646
- Release Date:2018/09/14 15:10
-
Relationship between rotary switch and axis number
When the rotary switch is “0”, the 1st axis and is “1”, the 2nd axis. When the rotary switch is “A”, the 11th axis and is “F”, the 16th axis. In combination ... More Details >>
- No:23644
- Release Date:2018/09/14 15:10
-
“off” is shown in the display.
Operation mode for manufacturer setting is enabled. For MR-J4-B, MR-J4W2-B and MR-J4W3-B, turning "ON (up)" all the control axis setting switches (SW2) enabl... More Details >>
- No:23625
- Release Date:2018/09/14 15:10
-
You can solder the wiring to the connector without using the junction terminal block (option). More Details >>
- No:23654
- Release Date:2018/09/14 15:10
-
Use the option cable, “MR-J3CN6CBL1M” for the analog monitor of MR-J4-A. More Details >>
- No:23655
- Release Date:2018/09/14 15:10
-
- No:23649
- Release Date:2018/09/14 15:10
-
Is the forced stop signal wiring necessary?
For the safety of use, the wiring is recommended. If not using the wiring, set the parameter No. PA04 to “0100”. More Details >>