Start main contents

Factory Automation

FAQ

Factory Automation

FAQAbout Products

  • Font Size
  • S
  • M
  • L

FAQ within [ Q17nDCPU ]

11-20 of Total 20

prev 2 / 2page next
  • Speed limit value change during operation

    No, the speed limit cannot be changed during operation. More Details >>

    • No:23571
    • Release Date:2018/09/14 15:09
  • Minor error120

    Minor error 120 occurs in the following case:The zero pass signal (M2406+20n) is OFF when the re-movement to the home position is performed by proximity dog,... More Details >>

    • No:23559
    • Release Date:2018/09/14 15:09
  • Servo motor rotation direction

    To reflect the change, set "[PA14] Rotation direction selection/traveldirection selection" and cycle the servo amplifier or execute a home position return af... More Details >>

    • No:23579
    • Release Date:2018/09/14 15:09
  • Virtual servomotor

    Check the following signals. • Start accept flag (M2001 to M2032) • Positioning start complete signal (M4000+20n (n: Axis No.-1)) More Details >>

    • No:23552
    • Release Date:2018/09/14 15:09
    • Update:2023/02/08 10:39
  • Deceleration stop

    Because the rapid stop deceleration time is larger than the deceleration time.Set the rapid stop deceleration time within the range of 1 to the deceleration ... More Details >>

    • No:23550
    • Release Date:2018/09/14 15:09
  • Rapid stop signal

    The rapid stop deceleration time of parameter block is applied.However, when the rapid stop deceleration time is set in the servo program, the value is enabl... More Details >>

    • No:23557
    • Release Date:2018/09/14 15:09
  • Acceleration/deceleration time change

    No, the time cannot be changed during operation. (Note): The following is the modules that support the acceleration/deceleration change function. • Q17nDSCP... More Details >>

    • No:23570
    • Release Date:2018/09/14 15:09
  • PCPU READY complete flag (SM500)

    The PCPU READY complete flag (SM500) turns ON when no error is detected in the fixed parameters, servo parameters, and limit switch output data, which are ch... More Details >>

    • No:23564
    • Release Date:2018/09/14 15:09
  • Battery holder unit

    Yes, they are included.In addition, a battery (Q6BAT) is also included. More Details >>

    • No:23576
    • Release Date:2018/09/14 15:09
  • Speed change during operation

    Specify the target axes during operation, and execute the following speed change request instruction. (1) Motion SFC program/Motion program Speed change requ... More Details >>

    • No:23573
    • Release Date:2018/09/14 15:09

11-20 of Total 20

Inquiries